2.3 INFORMATION GÉNÉRALE
POUR VOTRE SATISFACTION, CET ENCASTRÉ A ÉTÉ MIS À L’ESSAI POUR CONFIRMER SON
FONCTIONNEMENT ET SA QUALITÉ!
61,4 %
GDI44
Cote énergétique des foyers à gaz
Basée sur la norme CSA P.4.1-02
Modèle no
2.4 INFORMATION SUR LA PLAQUE D’HOMOLOGATION
W385-0252 / F
SERIAL NUMBER
NO. DE SERIE
GDI / CDI-44
GDI-44N / CDI-44N MODEL GDI-44P / CDI-44P
0 - 4500FT ALTITUDE/ELEVATION 0 - 4500FT
40,000 BTU/h INPUT / ALIMENTATION 40,000 BTU/h
13,000 BTU/h REDUCED INPUT / ALIMENTATION REDUITE 10,000 BTU/h
THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACE
ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE
FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN
THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY
STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE
USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE
BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH
SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX
ETATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS
MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME
D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU
CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS
DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA
501A.
MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS ARE 7 FEET AND 40 FEET
RESPECTIVELY. LES LONGUEURS VERTICALES MINIMALES ET MAXIMALES SONT 7
PIEDS ET 40 PIEDS RESPECTIVEMENT.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR : 3.5" D'UNE COLONNE D'EAU(GN) / 10" D'UNE COLONNE
D'EAU (P)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG) / 11" W.C. (LP)
PRESSION D'ALIMENTATION MIN : 4.5" D'UNE COLONNE D'EAU (GN) / 11" D'UNE
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX : 7" D'UNE COLONNE D'EAU (GN) / 13" D'UNE
COLONNE D'EAU (P)
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENT AVEC CETTE
UNITE.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
AVERTISSEMENT : N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC
CET APPAREIL PAR LE FABRICANT.
ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS.
SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER
REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE VENTAIR
INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION
PROPRE A WOLF STEEL. REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE
POUR L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
WARNING: FOR INSTALLATION INTO A VENTED NON-COMBUSTIBLE FIREPLACE
ONLY. THE MINIMUM FIREPLACE SIZE IS: HEIGHT 21”, DEPTH 16”, WIDTH 32”. THE
MINIMUM INSIDE FLUE SIZE IS 7”. THE MINIMUM DISTANCE, FROM THE BOTTOM OF A
COMBUSTIBLE MANTLE PROJECTING A MAXIMUM 3” FROM THE WALL TO THE TOP OF
THE STANDARD TRIM IS 12”. SEE OWNERS MANUAL FOR GREATER EXTENSIONS.
A HEARTH MUST PROTRUDE A MINIMUM OF 12” FROM THE UNIT.
ATTENTION : POUR INSTALLATION DANS UN FOYER VENTILE EN MACONNERIE.
LES DIMENSIONS MINIMUMS SONT: HAUTEUR 21”, PROFONDEUR 16”, LARGEUR 32”. LE
DIAMETRE INTERIEUR MINIMUM DE CONDUIT D’EVACUATION EST DE 7”.
LA DISTANCE MINIMALE, DU BAS DU MANTEAU COMBUSTIBLE FORMANT UNE
PROJECTION MAXIMALE DE 3” DU MUR AU DESSUS DE LA GARNITURE NORMALE EST
12”. REFERER AU MANUEL D’INSTALLATION POUR DES EXTENSIONS PLUS GRANDES.
UNE DALLE DE PROTECTION INCOMBUSTIBLE DOIT SE PROLONGER D’AU MOINS 12" DE
L’UNITÉ.
NOT FOR USE WITH SOLID FUEL / UN COMBUSTIBLE
SOLIDE NE DOIT PAS ETRE UTILSE AVEC CET APPAREIL
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
9700539 (WSL) 4001657 (NGZ)
4001658 (NAC) 4001659 (WUSA)
CERTIFIED UNDER: CSA 2.22b-2009, ANSI
Z21.50b-2009 VENTED GAS FIREPLACE.
HOMOLOGUE SELON LES NORMES: CS A
2.22b-2009, ANSI Z21.50b-2009 FOYER
GAZ AVEC EVACUATION.
A COUCHER, UNE SALLE DER, UNE SALLE DE
DANS UNE MAISON MOBILE SISON MOBILE SI
LA NORME CAN/CSA Z240MH A Z240MH
EN VIGUEUR AU CANADA OU AUX UEUR AU CANADA OU AUX
CONSTRUCTION DE MAISONSRUCTION DE MAISON
280. DANS LE CAS OU CETTE NORMANS LE CAS OU CETTE NOR
SE REFERER A LA NORME RELATIVEFERER A LA NORME RELATIV
ONTRE L'INCENDIE POUR LES INSTAL'INCENDIE POUR LES INSTA
S, LES SITES ET LES COMMUNAUTESSITES ET LES COMMUNAUTE
AL VENT LENGTHS ARE 7 FEET ANDNT LENGTHS ARE 7 FEET A
URS VERTICALES MINIMALES ET MAERTICALES MINIMALES ET MA
3.5 INCHES W.C. (NG) / 10 INCHES W.HES W.C. (NG) / 10 INC
3.5" D'UNE COLONNE D'EAU 3.5" D'UNE COLONNE D'E
4.5" W.C.(NG) / 11" W.C. (LP)W.C.(NG) / 11" W.C. (LP)
LIMENTATION MIN :TATION MIN :
4.5" D'UNE COLO 4.5" D'UN
7" W.C. (NG) / 13" W 7" W.C. (NG) / 13" W
ION D'ALIMENTATION MAX :TION MAX
OR USE WITH GLASS DOORS CERTIWITH GLASS DOORS CERT
UTILISER AVEC LES PORTES VITREAVEC LES PORTES VITRE
WARNING:
DO NOT ADD ANY MDO NOT ADD ANY
CONTACT WITH THE FLAMECONTACT WITH THE FL
WITH THE APPLIAN
E
AVERTISSEMENT
ENTRER EN CONTAENTRER EN CONTA
CET APPAREIL PACET APPAREIL P
INSTALLATEUR : Il est de votre responsabilité
de cocher les cases appropriées sur la plaque
d'homologation correspondant au modèle, au type
d'évacuation et au type de gaz de l'appareil.
Pour l’emplacement de la plaque d’homologation, voir la
section « VUE D’ENSEMBLE DE L’INSTALLATION ».
Cette illustration est à titre de référence seulement.
Consultez la plaque d’homologation pour obtenir
l’information précise.
6
W415-0734 / B / 02.06.12
Lorsque l'appareil est installé à des élévations dépassant 4 500 pieds, et en l’absence de recommandations
spéci ques de l’autorité compétente locale, l’indice certi é du débit à haute altitude devra être réduit au taux de 4
% pour chaque 1 000 pieds supplémentaires.
Les bruits causés par l’expansion et la contraction lors des cycles de chauffage et de refroidissement sont tout à
fait normaux et il faut s’y attendre.
Pour obtenir une réduction de débit maximale, le brûleur arrière doit être éteint. Pour plus d'information, voir les
Instructions de fonctionnement dans le manuel d'instructions.
Cet appareil n’est pas approuvé pour installation dans un placard ou en retrait. Il est approuvé pour installation
dans les salles de bain, les chambres à coucher et les chambres studio et convient pour installation dans les
maisons mobiles. Le modèle au gaz naturel peut être placé dans une maison mobile installée en permanence et
alimentée au gaz naturel.
Cet appareil ne doit être encastré que dans un foyer à bois ventilé incombustible (préfabriqué ou en maçonnerie).
GDI44
GN PL
Altitude (PI) 0-4 500 0-4 500
Débit max. (BTU/h) 40 000 40 000
Rend. max. (BTU/h) 27 600 27 600
Ef cacité (souf. allumée) 69 % 69 %
Pression minimale
d'alimentation en gaz
4,5" colonne d'eau 11" colonne d'eau
Pression maximale
d'alimentation en gaz
7" colonne d'eau 13" colonne d'eau
Pression au collecteur
(lorsque le gaz circule)
3,5" colonne d'eau 10" colonne d'eau