Amprobe AM-500 DIY-PRO Digital Multimeter Manuel utilisateur

Catégorie
Testeurs de réseau câblé
Taper
Manuel utilisateur
AM-500
Autoranging
Multimeter
EN FR
ES
User Manual
AM-500
Autoranging Multimeter
User Manual
10/2017, 4275548 A
©2017 Amprobe Test Tools.
All rights reserved. Printed in China
English
Limited Warranty and Limitation of Liability
Your Amprobe product will be free from defects in material and
workmanship for one year from the date of purchase unless
local laws require otherwise. This warranty does not cover fuses,
disposable batteries or damage from accident, neglect, misuse,
alteration, contamination, or abnormal conditions of operation
or handling. Resellers are not authorized to extend any other
warranty on the behalf of Amprobe. To obtain service during the
warranty period, return the product with proof of purchase to an
authorized Amprobe Service Center or to an Amprobe dealer or
distributor. See Repair Section for details. THIS WARRANTY IS YOUR
ONLY REMEDY. ALL OTHER WARRANTIES - WHETHER EXPRESS,
IMPLIED OR STATUTORY - INCLUDING IMPLIED WARRANTIES OF
FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE
HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE
FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY.
Since some states or countries do not allow the exclusion or
limitation of an implied warranty or of incidental or consequential
damages, this limitation of liability may not apply to you.
Repair
All Amprobe returned for warranty or non-warranty repair or
for calibration should be accompanied by the following: your
name, company’s name, address, telephone number, and proof of
purchase. Additionally, please include a brief description of the
problem or the service requested and include the test leads with
the meter. Non-warranty repair or replacement charges should be
remitted in the form of a check, a money order, credit card with
expiration date, or a purchase order made payable to Amprobe.
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before
requesting repair. During the warranty period, any defective
test tool can be returned to your Amprobe distributor for an
exchange for the same or like product. Please check the “Where
to Buy” section on amprobe.com for a list of distributors near you.
Additionally, in the United States and Canada, in-warranty repair
and replacement units can also be sent to an Amprobe Service
Center (see address below).
Non-warranty Repairs and Replacement – United States and Canada
Non-warranty repairs in the United States and Canada should be
sent to an Amprobe Service Center. Call Amprobe or inquire at your
point of purchase for current repair and replacement rates.
USA: Canada:
Amprobe Amprobe
Everett, WA 98203 Mississauga, ON L4Z 1X9
Tel: 877-AMPROBE (267-7623) Tel: 905-890-7600
Non-Warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Beha-Amprobe
distributor for a nominal charge. Please check the “Where to Buy”
section on beha-amprobe.com for a list of distributors near you.
Beha-Amprobe
Division and reg. trademark of Fluke Corp. (USA)
Germany
* United Kingdom
In den Engematten 14 52 Hurricane Way
79286 Glottertal Norwich, Norfolk
Germany NR6 6JB United Kingdom
Phone: +49 (0) 7684 8009 - 0 Phone: +44 (0) 1603 25 6662
beha-amprobe.de beha-amprobe.com
The Netherlands - Headquarters
**
Science Park Eindhoven 5110
5692 EC Son
The Netherlands
Phone: +31 (0) 40 267 51 00
beha-amprobe.com
*(Correspondence only – no repair or replacement available from this address.
European customers please contact your distributor.)
**single contact address in EEA Fluke Europe BV
AM-500 Autoranging Mulitmeter
8
7
1
32
4
5
6
1
LCD Display
2
SELECT Button
3
DATA HOLD Button
4
Rotary Switch
5
Input Terminal for voltage, diode, resistance and
continuity measurement
6
Input Terminal for battery test and AC/DC mA or μA
measurement
7
Input Terminal for AC/DC A measurement to10A
8
COM (return) terminal for all measurements
1
The Meter selects the range with best resolution
2
Direct Current
3
Alternate Current
4
Negative reading
5
Data hold
6
Diode test
7
Continuity test
8
Measurement units for resistance test
9
Measurement units for voltage test
10
Measurement units for current test
11
Low battery indicator
12
Battery Test
Screen Display
12
11
10
8
9
4
3
2
5
1
6 7
1
CONTENTS
SYMBOLS ............................................................................ 2
SAFETY INFORMATION ......................................................2
UNPACKING AND INSPECTION ..........................................4
FEATURES ............................................................................4
MAKING MEASUREMENT .................................................. 5
Rotary Switch Positions .................................................. 5
SELECT Button ................................................................ 6
DATA HOLD Button ........................................................ 6
Auto Power OFF ............................................................. 6
Measuring AC and DC Voltage ...................................... 6
Measuring Resistance .................................................... 7
Measuring Continuity .................................................... 7
Measuring Diode ............................................................ 8
Battery Test .....................................................................8
Measuring AC and DC Current ...................................... 9
SPECIFICATION ....................................................................10
MAINTENANCE AND REPAIR .............................................14
BATTERY AND FUSE REPLACEMENT .................................. 15
2
SYMBOLS
Caution ! Risk of electric shock.
Caution! Refer to the explanation in this Manual
Alternating Current (AC)
Direct Current (DC)
The equipment is protected by double insulation
or reinforced insulation
Earth (Ground)
Audible tone
Battery
Complies with European Directives
Conforms to relevant Australian standards
Canadian Standards Association (NRTL/C)
Do not dispose of this product as unsorted
municipal waste. Contact a qualified recycler.
SAFETY INFORMATION
The Meter complies with:
IEC/EN 61010-1 3rd Edition, UL61010-1 2nd Ed. and CAN/
CSA-C22.2 No. 61010-1-04 + CSA Update No.1: 2008 to
Category III 600 Volts, Pollution degree 2
IEC/EN 61010-2-030
IEC/EN 61010-2-31 for test leads
EMC IEC/EN 61326-1
“This product has been tested to the requirements of
CAN/CSA-C22.2 No. 61010-1, second edition, including
Amendment 1, or a later version of the same standard
incorporating the same level of testing requirements”.
Measurement Category III (CAT III) is for measurements
performed in the building installation. Examples are
measurements on distribution boards, circuit- breakers,
wiring, including cables, bus-bars, junction boxes,
3
switches, socket-outlets in the fixed installation, and
equipment for industrial use and some other equipment,
for example, stationary motors with permanent
connection to the fixed installation.
CENELEC Directives
The instruments conform to CENELEC Low-voltage
directive 2006/95/EC and Electromagnetic compatibility
directive 2004/108/EC
Warning: Read Before Using
• To avoid possible electrical shock or personal injury,
follow these instructions and use the Meter only as
specified in this manual.
• Do not use the Meter or test leads if they appear
damaged, or if the Meter is not operating properly.
If in doubt, have the Meter serviced.
• Always use the proper function and range for
measurements.
• Before rotating the function range selection switch,
disconnect test probe from circuit under test.
• Verify the Meter’s operation by measuring on a
known voltage source.
• Do not apply more than the rated voltage, as
marked on the Meter, between the test probe or
between any test probe and earth ground.
• Use the Meter with caution for voltages above 30
Vac rms, 42 Vac peak, or 60 Vdc. These voltages pose
electrical shock hazards.
• Disconnect circuit power and discharge all high-
voltage capacitors before testing resistance.
• Do not use the Meter around explosive gas or vapor.
• When using the test leads, keep your fingers behind
the finger guards.
• Remove test leads from the Meter before opening
the Meter case or battery door.
• if the meter is used in a manner not specified in
the users manual, the protection provided by the
equipment may be impaired
4
UNPACKING AND INSPECTION
Your shipping carton should include:
1 AM-500 Multimeter
1 Pair of test leads
2 1.5V alkaline AAA battery (installed)
1 Users manual
If any of the items are damaged or missing, return
the complete package to the place of purchase for an
exchange.
FEATURES
Easy to use digital multimeter designed for the
homeowner or DIY enthusiast. Install, troubleshoot or
repair light fixtures, fans, appliances, or automotive
electrical problems with easy and safety of a CAT III 600V
rated product. Check for voltage in electrical sockets,
extension cords, batteries and other electrical circuits. Let
the power of a professional Amprobe multimeter keep
you safe and help you solve all your electrical challenges.
• Measurements: Voltage up to 600V AC/DC, AC/DC
Current and Resistance
• Audible continuity
• Diode Test
• Data hold
• Auto power off
• Low battery warning
• Safety: CAT III 600V
5
MAKING MEASUREMENT

1. Use the proper function and range for
measurements.
2. To avoid possible electrical shock, personal injury or
damages to the Meter, disconnect circuit power and
discharge all high-voltage capacitors before testing
resistance and diode.
3. Connecting test leads:
• Connect the common (COM) test lead to the circuit
before connecting the live lead.
• After measurement, remove live lead before
removing the common (COM) test lead from the
circuit.
4. Symbol “OL” is displayed on LCD when the
measurement is out of range.
Rotary Switch Positions
Switch Position Measurement Function
V
AC or DC voltage measurement (use
SELECT button for switching to AC
or DC).
Resistance measurement
Voltage measurement of diode PN
junction
Continuity measurement
9V
For measurement of dry batteries of
not exceeding 15Vdc
1.5V
For measurement of dry batteries of
not exceeding 2Vdc
μA
mA A
AC or DC current measurement (use
SELECT button for switching to AC
or DC).
6
Button
SELECT
Press to select altemate measurement
functions on the rotary switch.
DATA
HOLD
Display freezes present reading
SELECT Button
Press the yellow SELECT button to select alternate
measurement functions on the rotary switch.
DATA HOLD Button
Press DATA HOLD button to freeze present reading on
display. Press again to resume normal operation.
Auto Power OFF
Auto power off: approx. 15 minutes.
When the Meter is in auto power off mode, press SELECT
or DATA HOLD button to resume normal operation.
Measuring AC and DC Voltage
Press SELECT button to switch to DC voltage
measurement function.
Do not apply on a voltage source higher than
AC/DC 600V.
7
Measuring Resistance
Disconnect circuit power and discharge all
high-voltage capacitors before testing resistance.
Note: On a higher resistance measurement (>1MΩ), the
measurement may take a few seconds to get stable reading.
Measuring Continuity
Disconnect circuit power and discharge all high-
voltage capacitors before testing continuity.
8
Measuring Diode
Disconnect circuit power and discharge all high-
voltage capacitors before testing diode.
Battery Test
Applying a voltage source or incorrect battery type
under battery test may cause personal Injury or damage
to the Meter.
Battery 1.5V range is for dry battery not exceeding 2Vdc.
The resistance load is around 30Ω.
Battery 9V range is for dry battery not exceeding 15Vdc.
The resistance load is around 1KΩ.The resistance load is
around 1KΩ.
9
Measuring AC and DC Current
Press SELECT button for switching to DC current
measurement function.
To avoid personal injury or damage to the Meter:
1. Do not attempt to make an in-circuit current
measurement when the open-circuit potential to
earth ground exceeding 600 V.
2. Switch to proper function and range for your
measurement.
3. Do not place the test probe in parallel with a circuit
when the test leads are connected to the current
terminals.
4. Connect the test leads to the correct input A/mA μA
current terminal and to the circuit before powering
the circuit under test.
5. After measurement, switching OFF the circuit’s
power before removing test leads from the circuit.
or
for
for
For current range from 8-10A, do not measure current
for more than one (1) minute. Wait for 10 minutes
before taking another measurement.
10
SPECIFICATION
Ambient temperature: 23°C ±5°C (73.4°F ±9°F)
Relative temperature: 75%
Accuracy: ±(% of reading + digits)
Maximum voltage between input terminal and earth
ground: AC 600Vrms or DC 600V
Fuse for mA μA input:
0.5A H 660V fast-fuse, 6.3x32mm
Fuse for 10A input:
10A H 660V fast-fuse, 6.3x32mm
Maximum display: 1999, updates 2 to 3/sec
Over-range indication: OL
Range: Automatic
Altitude: Operating 2000m
Operating temperature: 0°C ~ +40°C (32°F ~ 104°F)
Relative humidity: 0°C ~ +30°C (32°F ~ 86°F) 75%; +30°C
~ +40°C (86°F ~ 104°F) 50%
Storage temperature: -10°C ~ +50°C (14°F ~ 122°F)
Electromagnetic compatibility: In an RF filed of 1V/m =
Specified accuracy ±5%
Battery: 2 x 1.5V AAA alkaline battery or equivalent
Low battery indication:
Dimensions (L x W x H): 150 mm x 83 mm x 40 mm (5.9 in
x 3.3 in x 1.6 in)
Weight: Approx. 290g (0.64lb) with batteries installed
11
1. DC Voltage Measurement
Range Resolution Accuracy
200.0mV 0.1mV ±(0.8%+3dgt)
2.000V 1mV
±(0.8%+1dgt)20.00V 10mV
200.0V 100mV
600V 1V ±(1.0%+3dgt)
Input impedance: around 10M; (Input impedance > 3G
for DC 200mV range)
Overload protection: 600VDC or AC rms
2. AC Voltage Measurement
Range Resolution Accuracy
2.000V 1mV
±(1.0%+3dgt)20.00V 10mV
200.0V 100mV
600V 1V ±(1.2%+3dgt)
Input impedance: around 10M
Frequency response: 45Hz ~ 400Hz
Overload protection: 600VDC or AC rms
3. Resistance Measurement
Range Resolution Accuracy
200.0Ω 0.1Ω
±(1.2%+5dgt) at 5Ω
±(1.2%+3dgt) at >5Ω
2.000kΩ 1Ω
±(1.0%+2dgt)20.00kΩ 10Ω
200.0kΩ 100Ω
2.000MΩ 1kΩ ±(1.2%+2dgt)
20.00MΩ 10kΩ ±(1.5%+5dgt)
12
200Ω range: Measured value = (Measured display value)
– (Short-circuiting value of probe)
Open circuit voltage: around 0.5V
Overload protection: 600V
4. : Continuity : Diode measurement
Range Resolution Accuracy
0.1Ω
Open circuit voltage is around 0.5V.
Resistance >150Ω, buzzer will not
sound.
Resistance 10Ω, buzzer will sound.
11 < Resistance < 150.........Not
Specified.
1mV
Open-circuit voltage is around 1.5V.
Normal voltage is around 0.5V to
0.8V for silicon PN junction.
Overload protection: 600V
5. Battery Test
Range Resolution Accuracy
1.5V
10mV ±(10%+3dgt)
9V
Overload protection:
F1 fuse, 0.5A H 660V fast-fuse, 6.3x32mm
For 1.5V range: Load resistance is around 30Ω.
For 9V range: Load resistance is around 1kΩ.
13
6. DC Current Measurement
Range Resolution Accuracy
μA
200.0μA 0.1μA
±(1.0%+2dgt)
2000μA 1μA
mA
20.00mA 10μA
200.0mA 0.1mA
A
2.000A 1mA
±(1.2%+3dgt)
10.00A 10mA
Overload protection:
mA /μA input:
F1 fuse, 0.5A H 660V fast-fuse, 6.3x32mm
10 A input:
F2 fuse, 10A H 660V fast-fuse, 6.3x32mm
7. AC Current Measurement
Range Resolution Accuracy
μA
200.0μA 0.1μA
±(1.2%+2dgt)
2000μA 1μA
mA
20.00mA 10μA
200.0mA 0.1mA
A
2.000A 1mA
±(1.5%+3dgt)
10.00A 10mA
Frequency response: 45Hz ~ 400Hz
Overload protection:
mA /μA input:
F1 fuse, 0.5A H 660V fast-fuse, 6.3x32mm
10 A input:
F2 fuse, 10A H 660V fast-fuse, 6.3x32mm
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71

Amprobe AM-500 DIY-PRO Digital Multimeter Manuel utilisateur

Catégorie
Testeurs de réseau câblé
Taper
Manuel utilisateur