Installing the ACA 11-...
Plug the ACA11-... onto the V.24, the Mini-DIN or the M12 terminal of the device.
Note: When you restart, the device always assumes the configuration data of the ACA and saves
them permanently into the flash memory. Wether the configuration data of the ACA coincides with
the configuration data of the device, shows you the status of the AutoConfiguration Adapter in the
Web-based Interface or Command Line Interface.
Notes:
- The ACA11-... is intended for use and connection only to listed Hirschmann Industrial Ethernet
products providing Limited Power Source according to the EN 60950-1
requirements.
Maximum Electrical Ratings: U
in
: ± 15 V, I
in
: 3 mA.
- The ACA11-... is intended for use without an additonal extension-cable.
- Peripheral equipment must be suitable for the location it is used in.
Relevant Information for Europe (EU) for Use in Zone 2 Explosive Atmosphere:
This product may be operated in EX zone 2 only if the product label is marked as follows:
II 3G Ex nA IIC T4 Gc DEKRA 12ATEX0258X
Temperature Code: T4; Ta: 0 °C to +60 °C (standard) -or-
Temperature Code: T4; Ta: −40 °C to +70 °C for “EEC” and “(EEC)” types only (extended)
- refer to the type designation on the device.
Special conditions for safe use:
The ACA11-... modules must be installed in a suitable enclosure in accordance with EN60079-15,
taking into account the environmental conditions under which the equipment will be used.
Relevant Information for North America: Only for connection with a Class 2 power supply.
Max. surrounding air temperature:
+60° C max. - For “EEC” and “(EEC)” types only: +70° C max.
Additional Information for Use in Hazardous Locations (North America):
For Use with Class 2 Industrial-Line Hirschmann Ethernet products (host) only if this product
(host) is “FOR USE IN IN HAZARDOUS LOCATIONS”- follow the labelling/ installation
instructions of the host.
ACA11 devices may be operated in hazardous locations only if the product label is marked
accordingly. The following information applies when operating the ACA11 devices in hazardous
locations:
INDUSTRIAL CONTROL EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS.
CLASS I, DIVISION 2, Groups A, B, C and D;
TEMPERATURE CODE T4 AND AMBIENT TEMPERATURE Ta +60° C max.
- For “EEC” and “(EEC)” types only: Ta +70° C max..
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER
HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON - HAZARDOUS.
TO BE SUPPLIED BY A CLASS 2 POWER SUPPLY OR ISOLATED LOW VOLTAGE LIMITED
ENERGY (LVLE).
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR
SUITABILITY FOR DIVISION 2.