Extron electronics TLI Pro 201 Manuel utilisateur

Taper
Manuel utilisateur
68-3514-01 Rev. A
08 20
TouchLink Pro Interface Control Systems
TLI Pro 201
User Guide
TouchLink
®
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within the
product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer darauf
aufmerksam machen, dass im Inneren des Gehäuses dieses Produktes
gefährliche Spannungen herrschen, die nicht isoliert sind und die einen
elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in der
im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise
zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie
in den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y
temas relacionados, consulte la Guía de cumplimiento de normativas
y seguridad de Extron, referencia 68-290-01, en el sitio Web de Extron,
www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad
avvertire l’utente della presenza di tensione non isolata pericolosa
all’interno del contenitore del prodotto che può costituire un rischio di
scosse elettriche.
ATTENTZIONE: Il simbolo, , se usato sul prodotto, serve ad
avvertire l’utente della presenza di importanti istruzioni di funzionamento e
manutenzione nella documentazione fornita con l’apparecchio.
Per informazioni su parametri di sicurezza, conformità alle normative,
compatibilità EMI/EMF, accessibilità e argomenti simili, fare riferimento
alla Guida alla conformità normativa e di sicurezza di Extron, cod. articolo
68-290-01, sul sito web di Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma na celu
poinformować użytkownika o obecności izolowanego i niebezpiecznego
napięcia wewnątrz obudowy produktu, który może stanowić zagrożenie
porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposażone w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji
wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy
pokrewne, zobacz Extron bezpieczeństwa i regulacyjnego zgodności
przewodnik, część numer 68-290-01, na stronie internetowej Extron,
www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению
электрическим током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
www.extron.com, номер по каталогу - 68-290-01.
安全说明 简体中文
警告 产品上的个标志意在警告用户该产品机壳内有暴露的危险 电压,
险。
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修说明。
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 , www.extron.com,参见
Extron 安全规范指南,产品编号 68-290-01
Safety Instructions
安全記事 • 繁體中文
警告: 若產品上使用此是為了提醒使用者產品機殼內存
可能會導致觸電之風險的未絕緣危險電壓
注意 品上使用此符號,提醒使用者設備隨附的用手冊中
護( )説
有關安全性指導方法規遵守EMI/EMF 相容取範圍和相關主題的詳細
資訊請瀏覽 Extron 網站www.extron.com然後參閱Extron 安全性與
法規遵守手冊則編號 68-290-01
安全上の注意
日本語
警告: この が製品上に表示されている場合は、筐体内に絶縁され
いない高電圧が流れ、感電の危険があることています
意:この が製品上に表されている場合はの取書に
されている重作と保()のについてユザー
を喚起するものです
安全上の注意、法規厳守、EMI/EMF適合性、その他の関連項目
スト イト www.extron.com よ り Extron Safety
and Regulatory Compliance Guide』 ( P/N 68-290-01) をご覧ださい
안전 지침 • 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합
니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에 대한
자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및 규제 준수
안내서, 68-290-01 조항을 참조하십시오.
Copyright
© 2020 Extron. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks®, registered service marks(SM), and trademarks(TM) are the property of RGBSystems, Inc. or Extron (see the
current list of trademarks on the Terms of Use page at www.extron.com):
Registered Trademarks
(
®
)
Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, eLink, Extron, Flat Field, FlexOS, Glitch Free, Global
Configurator, Global Scripter, GlobalViewer, Hideaway, HyperLane, IP Intercom, IP Link, Key Minder, LinkLicense, LockIt, MediaLink, MediaPort,
NAV, NetPA, PlenumVault, PoleVault, PowerCage, PURE3, Quantum, ShareLink, Show Me, StudioStation, SoundField, SpeedMount,
SpeedSwitch, System INTEGRATOR, TeamWork, TouchLink, VideoLounge, V-Lock, VN-Matrix, VoiceLift, WallVault, WindoWall, XPA, XTP,
XTP Systems, and ZipClip.
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-Rate Frame Lock), ADSP (Advanced Digital Sync Processing), Auto-Image, AVEdge, CableCover, CDRS (Class D
Ripple Suppression), Codec Connect, DDSP (Digital Display Sync Processing), DMI (Dynamic Motion Interpolation), DriverConfigurator,
DSPConfigurator, DSVP (Digital Sync Validation Processing), EQIP, Everlast, FastBite, Flex55, FOX, FOXBOX, IP Intercom HelpDesk, MAAP,
MicroDigital, Opti-Torque, PendantConnect, ProDSP, QS-FPC (QuickSwitch Front Panel Controller), Room Agent, Scope-Trigger, SIS, Simple
Instruction Set, Skew-Free, SpeedNav, Triple-Action Switching, True4K, True8K, Vector™ 4K, WebShare, XTRA, and ZipCaddy
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is
likely to cause interference. This interference must be corrected at the expense of the user.
NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide on the Extron website.
Battery Notice
This product contains a battery. Do not open the unit to replace the battery. If the
battery needs replacing, return the entire unit to Extron (for the correct address, see the
Extron Warranty section on the last page of this guide).
CAUTION: Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used
Batteries According to the Instructions.
ATTENTION : Risque d’explosion. Ne pas remplacer la pile par le mauvais type de pile.
Débarrassez-vous des piles utilisées selon le mode d’emploi.
Conventions Used in this Guide
In this user guide, the following are used:
Notifications
WARNING: Potential risk of severe injury or death.
AVERTISSEMENT : Risque potentiel de blessure grave ou de mort.
CAUTION: Risk of minor personal injury.
ATTENTION : Risque de blessuremineure.
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
Software Commands
Commands are written in the fonts shown here:
NOTE: For commands and examples of computer or device responses mentioned
in this guide, the character “0” is used for the number zero and “O” represents the
capital letter “o”.
Computer responses and directory paths that do not have variables are written in the font
shown here:
C:\Program Files\Extron
Variables are written in slanted form as shown here:
ping xxx.xxx.xxx.xxx —t
SOH R Data STX Command ETB ETX
Selectable items, such as menu names, menu options, buttons, tabs, and field names are
written in the font shown here:
From the File menu, select New.
Click the OK button.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
Extron Glossary of Terms
A glossary of terms is available at www.extron.com/technology/glossary.aspx.
Contents
Introduction .............................................1
About the TLI Pro 201 ..........................................1
Features ............................................................... 1
Application Diagram .............................................2
Installation Overview .....................................3
Panel Features ...............................................5
TLI Pro 201 Rear Panel Features
and Connections .................................................5
Connecting Power ...........................................7
TLI Pro 201 Front Panel Features .......................10
On-screen Menus ........................................11
Setup Menu .......................................................11
Status ............................................................11
Network .........................................................12
Output ...........................................................14
Audio .............................................................16
Input ..............................................................17
Advanced ......................................................19
Calibration Screen .............................................. 20
Configuration Software ...............................22
Configuration Software ....................................... 22
Downloading Software .......................................22
Using the Software ............................................. 24
TLI Pro 201 Web Page ....................................... 25
Updating the Firmware .......................................26
Downloading Firmware ...................................26
Annotation ....................................................28
Annotation Overview ..........................................28
Local Annotation ............................................28
Remote Annotation ........................................28
Differences between TLI Pro 201 Local
and Remote Annotation ....................................29
Mounting ......................................................30
Wall Mounting ....................................................30
Rack Mounting ...................................................30
Underwriters Laboratories Guidelines
for Rack Mounting ........................................30
Other Mounting Options ..................................... 30
Reference Material ......................................31
Network Port Requirements and Licensed
Third-Party Software .........................................31
Reset Modes......................................................31
Use Factory Firmware ....................................32
Reset All IP Settings ....................................... 32
Reset to Factory Defaults ...............................33
Enable or Disable the DHCP Client .................33
Secure Sockets Layer (SSL) Certificates ............. 34
IEEE 802.1X Certificates .....................................34
Certificate File Requirements ..........................35
Private Key File Requirements ........................35
TLIPro201 • Contents vii
TLIPro201 • Contents viii
Introduction
This guide describes the function, installation, and operation of the TLI Pro 201. Unless
otherwise stated, the terms “interface” and “TouchLink Pro interface” also refer to this
model.
This section provides an overview of the TLI Pro 201:
About the TLI Pro 201
Features
Application Diagram
About the TLI Pro 201
The Extron TLI Pro 201 is a TouchLink Interface that allows a third-party 4K touchscreen
display to be used as a point of control within an Extron Pro Series control system. The
interface includes a scaled HDCP 2.3-compliant HDMI input for video preview, supporting
resolutions up to 4K @ 30 Hz. The scaled output supports signal resolutions up to
4K @ 30 Hz at 4:4:4.
The TLI Pro 201 has built in annotation features, allowing a presenter to draw and point
on 4K video or computer sources using a third-party touchscreen display or a mouse.
Features
Compatible with third-party touchscreen displays — Up to 4K @ 30 Hz at 4:4:4
Compatible with all IP Link Pro control processors and HC 400 Series
Meeting Space Collaboration Systems
HDCP 2.3-compliant HDMI Input — For full-motion video preview and monitoring
One high speed USB 2.0 port — For third-party touch displays or HID support
PoE+ compatible — Product is powered directly by a PoE+ switch or injector,
eliminating the need for bulky local power supplies.
Built in annotation features — Allows a presenter to draw and point on 4K video or
computer sources using a third-party touch display or a mouse.
User Interface and Annotation Toolbar are created and customized using GUI
Designer — Basic annotation tools are available for drawing freehand, highlighting an
area of an image, or pointing to an object on-screen. Customization options include
adding a drop shadow, point size and color.
Can be used in conjunction with Extron Annotator 300 — For advanced
annotation capabilities
Supports remote annotation — When more than one TLI Pro 201 or an
Annotator 300 is used in the same system
Ability to annotate on one TLI Pro 201 to multiple touch displays with
attached Extron annotation products
Fully customizable using Extron control system software — GUI Designer
combined with Global Configurator Plus, Global Configurator Professional, or
Global Scripter.
TLIPro201 • Introduction 1
Uses the same HID device drivers as the Annotator 300 and TLI Pro 101
Advanced Extron video signal processing with a high-performance scaling
engine
Automatic clock synchronization — Allows touchpanel to display the accurate
time and date
Adjustable sleep timer puts interface into sleep mode
Compact 1 inch (25 mm) high, half rack width metal enclosure low profile
enclosure — Allows discreet installation within a lectern or behind a flat panel display
Application Diagram
POWER
12V
1.0A MAX
IR/S
G
Tx Rx RTSCTS
COM 1
G
Tx Rx
COM 2
VCG
VOL
RELAYS
1 2C
1 23 4 G
DIGITAL I/O
PWROUT =6W
eBUS
+V +S
-S
G
LAN
AV
LAN
GS
DEVICE LAN/PoE
+
OUTPUTINPUT
RS-232
Tx Rx G
12
INPUT
REMOTE
OUTPUTS
POWER
12V
--A MAX
Extron
TLI Pro 201
4K TouchLink Interface
RS-232
RS-232
Ethernet
Ethernet
Ethernet
Ethernet/PoE+
4K 3rd Party Touchscreen
USB
HDMIHDMI
HDMI
HDMI
Extron
DA2 HD 4K Plus
Distribution Amplier
Laptop
Flat Panel Display
Extron
IPCP Pro 255Q xi
IP Link Pro Quad Cor
e
Control Processor
Science
Building
en
n
S
cienc
e
B
u
ildi
n
g
LAN
MODEL 80
FLAT PANEL
AV LAN
Figure 1. TLI Pro 201 Application Diagram
TLIPro201 • Introduction 2
Installation
Overview
1. Before starting, download and install the latest versions of the following software:
Toolbelt — Provides device discovery, device information, firmware updates,
and configuration of network settings, system utilities, and user management for
TouchLink Pro interfaces.
Global Configurator Professional and Global Configurator Plus — For
setting up and configuring the control processor, interface, and third-party
touchpanel.
GUI Designer — For designing layouts for Extron TouchLink Pro interfaces and
third-party touch interfaces.
Global Scripter — Provides an integrated development environment for Extron
control systems programming.
See Configuration Software on page 22.
2. Obtain the following network information from your network administrator:
DHCP setting (On or O). If the DHCP setting is off, you also need:
Interface IP address
Subnet mask
Gateway IP address
Usernames — By default these are either admin or user.
Passwords — The factory configured passwords for all accounts on this device
have been set to the device serial number. Passwords can be changed during
configuration. They are case sensitive.
NOTE: If the device is reset to default settings, the passwords are reset to
the default password, which are extron (for either admin or user).
MAC address — Make a note of the interface MAC address.
3. Mount the TLI Pro 201 in a standard rack, or use an under-table mounting kit
(see Mounting on page 30). To mount the third-party touch display follow the
instructions provided by the manufacturer.
4. Connect cables to the TLI Pro 201 (see TLI Pro 201 Rear Panel Features and
Connections on page 5).
Connect an HDMI source to the HDMI input of the TLI Pro 201 (figure 2,
A
, on
page 5) .
Connect the HDMI output from the TLI Pro 201 (
B
) to the third-party touch
display.
Connect the USB port from the TLI Pro 201 (
C
) to the third-party touch display.
NOTE: The USB connection passes information to the TLI Pro 201 about where on
the screen the touch display was pressed. If you are using a non-touch display,
connect a USB mouse to the USB port on the TLI Pro 201 and use the mouse
to click on screen buttons.
TLIPro201 • Installation Overview 3
5. Connect the Ethernet cable. The TLI Pro 201 must be powered by PoE+ (see
LAN/PoE+ Port on page 6).
ATTENTION:
Do not connect the power supply before reading the Attention on
page 8.
Veuillez lire la partie « mises en garde » page 8, avant de mettre sous
tension les écrans tactiles.
6. Set up the TLI Pro 201 for network communication:
Connect the PC that you will use for setup, the control processor, and the
TLI Pro 201 to the same Ethernet subnetwork.
Use the On-screen Menus (see page 11) or Toolbelt (see the Toolbelt Help
File) to set the DHCP status and, if necessary, the IP address, subnet mask,
gateway, and related settings for the interface.
7. Configure the interface
The Global Configurator Professional and Global Configurator Plus Help File and the
GUI Designer Help File provide step-by-step instructions and detailed information.
The Global Configurator Professional and Global Configurator Plus Help File
includes an introduction to the software and sections on how to start a project and
configuration.
Global Scripter provides an Extron-exclusive Python
library (ControlScript) and
Global Scripter modules to get you started. See the GlobalScripter Help File for more
information.
TLIPro201 • Installation Overview 4
Panel Features
This section describes:
TLI Pro 201 Rear Panel Features and Connections
TLI Pro 201 Front Panel Features
TLI Pro 201 Rear Panel Features and Connections
A
A
AB
B
BC
CCD
D
D
DEVICE LAN/PoE
+
OUTPUTINPUT
Figure 2. TLIPro201 Rear Panel
A
HDMI Input
B
HDMI Output
C
USB Port
D
LAN/PoE+ Port
A
HDMI Input — Plug the cable from the input source device into this female HDMI
type A port. Use the provided LockIt HDMI lacing bracket to secure the HDMI
connector (see Securing the HDMI Connector on page 9).
B
HDMI Output — Connect this female HDMI type A port to a third-party touch
display. Use the provided LockIt HDMI lacing bracket to secure the HDMI connector
(see Securing the HDMI Connector).
See the Output Screen Resolutions table on page 6 for a full list of video output
screen resolutions supported by the TLI Pro 201.
figure 2
HDMI Input
HDMI Output
TLIPro201 • Panel Features 5
TLI Pro 201 Output Screen Resolutions
Resolution 23.98 Hz 24 Hz 25 Hz 29.97 Hz 30 Hz 50 Hz 59.94 Hz 60 Hz
640x480 X
800x600 X
1024x768 X
1280x768 X
1280x800 X
1280x1024 X
1360x768 X
1366x768 X
1440x900 X
1400x1050 X
1600x900 X
1680x1050 X
1600x1200 X
1920x540 X
1920x720 X
1920x1200 X
480p X X
576p X
720p X X X X X X
1080p X X X X X X X Default
2048x1080 X X X X X X X X
2048x1200 X
2048x1536 X
2560x1080 X
2560x1440 X
2560x1600 X
3440x1440 X
3840x1080 X
3840x2160 X X X X X
4096x2160 X X X X X
Custom 1 Defaults to 1080p @ 60 Hz
Custom 2 Defaults to 1080p @ 60 Hz
Custom 3 Defaults to 1080p @ 60 Hz
C
USB Port (see figure 2 on page 5) — Supports High-speed USB 2.0 control.
Plug a USB cable from the third-party touch display into this female typeB connector.
The USB connection passes information to the interface about where the touch
display was pressed. To use a non-touch display, connect a mouse to this port. Use
the mouse to click screen icons.
D
LAN/PoE+ Port — The interface is compliant with the requirements of PoE+
(IEEE 802.3at, class 4) and must be powered by PoE+ power sourcing equipment
(PSE). Connect this port to either a PoE+ power injector (see Connecting Power on
page 7) or a PoE+ switch.
NOTE: The TLI Pro 201 does not include any PoE+ power sourcing equipment.
This must be purchased separately.
Output Screen Resolutions
USB Port
LAN/PoE+ Port
TLIPro201 • Panel Features 6
An Extron IPL Pro control processor must also be connected to the same network
domain as the TLI Pro 201. See the www.extron.com for a list of suggested models.
The network port has two LEDs. The green Link LED lights steadily to indicate that
the TLI Pro 201 is connected correctly to a network. The amber Activity LED blinks to
indicate that data is being passed to or from the TLI Pro 201.
Connecting Power
ATTENTION:
Do not connect the power supply before reading the Attention on page 8.
Veuillez lire la partie « mises en garde » page 8, avant de mettre sous tension
les écrans tactiles.
Extron recommends the Extron PI 140 power injector (see figure 3). Your power injector
may look different.
1. Use an Ethernet cable to connect the LAN/PoE+ port of the interface to the power
output of the 802.3at, class4 compliant PoE+ power injector.
This cable carries network information from the switch or router to the power supply
input.
2. Connect the network input of the power injector to a network switch or router.
This cable carries the network information and power from the power supply to the
interface.
3. Connect the IEC power cord to a convenient 100 VAC to 240 VAC, 50-60 Hz power
source.
100-240V
~
50-60Hz
0.4A MAX
XTP
PWR
XTP PWR
To network switchTo TLI Pro 201
Figure 3. Connecting the Power Injector
Alternatively, use an Ethernet cable to connect the LAN/PoE+ port of the interface to a
PoE+ switch.
figure 3
TLIPro201 • Panel Features 7
ATTENTION:
The TLI Pro 201 is intended for connection to a Power over Ethernet circuit for
intra-building use only and is considered to be part of a Network Environment 0 per
IEC TR62101.
Le TLI Pro 201 est conçu pour une connexion à un circuit PoE pour une utilisation
intérieure seulement et est considéré comme faisant partie d’un environnement
réseau 0 selon la norme IECTR62101.
Always use a power supply provided by or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and may
cause damage to the supply and the end product.
Utilisez toujours une source d’alimentation fournie ou recommandée par Extron.
L’utilisation d’une source d’alimentation non autorisée annule toute conformité
réglementaire et peut endommager la source d’alimentation ainsi que le produit final.
This product is intended for use with a UL Listed power source marked “Class 2” or
“LPS” and rated 48 VDC or 56 VDC (PoE), Minimum 0.8A.
Ce produit est destiné à une utilisation avec une source d’alimentation listéeUL
avec l’appellation «Classe2» ou «LPS» et normée 48Vcc ou 56 Vcc (PoE), 0,8A
minimum.
Extron power supplies are certified to UL/CSA 60950-1 and are classified as LPS
(Limited Power Source). Use of a non-LPS or unlisted power supply will void all
regulatory compliance certification.
Les sources d’alimentation Extron sont qualifiées UL/CSA60950-1 et sont
classéesLPS(LimitedPowerSource). L’utilisation d’une source d’alimentation non-
listée ou non-listéeLPS annulera toute certification de conformité réglementaire.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling
spaces or in wall cavities. The power supply is to be located within the same vicinity
as the Extron AV processing equipment in an ordinary location, Pollution Degree 2,
secured to the equipment rack within the dedicated closet, podium, or desk.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une
utilisation dans les espaces d’aération ou dans les cavités murales. La source
d’alimentation doit être située à proximité de l’équipement de traitement audiovisuel
dans un endroit ordinaire, avec un degré2 de pollution, fixé à un équipement de
rack à l’intérieur d’un placard, d’une estrade, ou d’un bureau.
Power over Ethernet (PoE) is intended for indoor use only. It is to be connected only
to networks or circuits that are not routed to the outside plant or building.
L’alimentation via Ethernet (PoE) est destinée à une utilisation en intérieur
uniquement. Elle doit être connectée seulement à des réseaux ou des circuits qui ne
sont pas routés au réseau ou au bâtiment extérieur.
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical
Code part 1, section 16.
Cette installation doit toujours être en accord avec les mesures qui s’applique au
National Electrical Code ANSI/NFPA70, article725, et au Canadian Electrical Code,
partie1, section16.
The power supply shall not be permanently fixed to the building structure or similar
structure.
La source d’alimentation ne devra pas être fixée de façon permanente à une
structure de bâtiment ou à une structure similaire.
Attention
mises en garde
TLIPro201 • Panel Features 8
Securing the HDMI Connector
Use a HDMI cable to connect the HDMI input or output to the female HDMI ports on the
front panel of the interface (figure 2,
A
or
B
, on page 5).
Use the provided LockIt HDMI lacing bracket to secure the HDMI connector:
1. Plug the HDMI cable into the panel connection.
2. Loosen the HDMI connection mounting screw from the panel enough to allow the
LockIt lacing bracket to be placed over it. The screw does not have to be removed.
3. Place the LockIt lacing bracket on the screw and against the HDMI connector, then
tighten the screw to secure the bracket.
ATTENTION:
Do not overtighten the HDMI connection mounting screw. The shield it
fastens to is very thin and can easily be stripped.
Ne serrez pas trop la vis de montage du connecteur HDMI. Le blindage
auquel elle est attachée est très fin et peut facilement être dénudé.
3
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
Figure 4. Securing the HDMI Connector
4.
Loosely place the included tie wrap around the HDMI connector and the LockIt lacing
bracket as shown.
5. While holding the connector securely against the lacing bracket, tighten the tie wrap,
then remove any excess length.
TLIPro201 • Panel Features 9
TLI Pro 201 Front Panel Features
A
A
AB
B
BC
C
CD
D
D
SIGNAL
INPUTOUTPUT
HDCP
TLI Pro 201
R MENU
Figure 5. TLI Pro 201 Plus Front Panel
A
Power LED — Indicates the power status and the reset status of the unit.
B
Reset button (recessed) — Allows the unit to be reset in any of three different
modes. It also allows the user to toggle between enabling and disabling the DHCP
client (see Reset Modes on page 31).
C
Menu button (recessed) — Opens the Setup Menu (see the next page) and
Calibration Screen (see page 20) for the interface:
Setup Menu
1. Press the button briefly (less than 3 seconds) to open the internal menu screens.
2. Press the button briefly for a second time to exit the setup menu.
Calibration Screen
1. Press and hold the button (3 seconds or more) to open the Calibration screen.
2. Follow the on-screen instructions to calibrate the touchpanel.
3. Complete the calibration process or press the button briefly (less than 2 seconds) for
a second time to exit the Calibration screen.
D
Status LEDs
The Signal LEDs light green when a video signal is detected and are unlit when
no signal is detected.
The HDCP LEDs light green when HDCP content is detected and are unlit when
HDCP content is not detected.
figure 5
TLIPro201 • Panel Features 10
On-screen Menus
On-screen menus allow initial configuration of the TLI Pro 201.
Setup Menu
Calibration Screen
Setup Menu
Press the recessed front-panel Menu button (see figure 5,
B
, on page 10) to access
the on-screen setup menu.
1. Press the button briefly (less than 3 seconds) to open the setup menu.
2. Press the button briefly a second time to exit the setup menu.
The menu opens at the Status screen. There are six different screens:
Status Audio
Network Input
Output Advanced
The screens are selected by pressing the appropriate button in the navigation panel at the
top of the screen.
Buttons that have been selected turn yellow. All other buttons are black. This is true of
both the buttons in the navigation panel and buttons on the various screens.
There is also a red Exit button in the top right corner of the screen. Pressing this button
applies and saves any changes and closes the menu screens.
Status
Info
Model: TLI Pro 201
Part Number: 60-1669-01
Firmware
Version:
1.00
Network
IP Address:
DHCP:
Host Name:
Off
192.168.254.251
TLI-AB-CD-EF
Output
TLI Output:
GUI Project:
Sleep Timer:
1080p @ 60Hz
1080p @ 60Hz
5 Minutes
Audio
Master Volume:
Master Mute: Off
99
Input
HDMI: No Signal
Status
Output
Audio
Advanced
Exit
Network
Input
Advanced
Controller IP: 192.168.254.250
Project Size: N/A
Bootloader
Version:
1.00
PoE Status:Active
Figure 6. Status Screen
This is a read-only screen. The Info panel provides basic information about the interface.
Each of the other five panels summarizes information from the other screens. Pressing any
of the panels opens the corresponding screen in exactly the same way as pressing the
buttons in the top navigation panel.
When there is a network connection, a green bubble shows in the Network panel. A red
square shows if there is no connection. When a control processor is connected, a green
bubble shows in the Advanced panel. A red square shows if none is connected.
TLIPro201 • On-screen Menus 11
Network
Verify with your network administrator whether the IP address for the TLI is assigned by
Dynamic Host Configuration Protocol (DHCP) or set manually. If they are set manually,
you need to obtain an IP Address, a Subnet Mask, a Gateway Address, and a Domain
Name Server (DNS) IP address from the network administrator.
Network
Status Output AudioInput Advanced Exit
DHCP
On
Off
192.168.254.253
192.168.254.254
255.255.0.0
0.0.0.0
XYZ-123-AB-CD-EFHost Name:
IP Address:
Subnet Mask:
Gateway:
DNS Primary:
Mac Address:
Domain Name:
xx-xx-xx-xx-xx-xx
abcdefghijklmnop...
ApplyRevert
Figure 7. Network Screen
1.
If the IP address is to be assigned by DHCP, press On. If the IP address is to be
assigned manually, press O.
When DHCP is off, the Host Name is grayed out and cannot be edited. All
addresses can be edited (as shown in figure 9 on page 13).
When DHCP is on, the Host Name can be edited. The addresses are grayed out
and cannot be edited because they are set by the DHCP server.
2. If DHCP is on, press the Host Name button to edit the host name. The Host Name
dialog box opens:
Figure 8. Host Name Dialog Box
Use the keypad to enter a new name, which appears in the Host Name text box.
TLIPro201 • On-screen Menus 12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Extron electronics TLI Pro 201 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues