Amprobe NCV-1020, NCV-1030 & NCV-1040 Manuel utilisateur

Taper
Manuel utilisateur
NCV-1000 Series
Non-Contact
Voltage Probe
User Manual
ENG FRE
SPA
NCV-1000 Series
Non-Contact Voltage
Probe
User Manual
7/2018, 6009474 Rev B
©2018 Amprobe
All rights reserved. Printed in China
English
Limited Warranty and Limitation of Liability
Your Amprobe product will be free from defects in material
and workmanship for one year from the date of purchase
unless local laws require otherwise. This warranty does
not cover fuses, disposable batteries or damage from
accident, neglect, misuse, alteration, contamination, or
abnormal conditions of operation or handling. Resellers
are not authorized to extend any other warranty on the
behalf of Amprobe. To obtain service during the warranty
period, return the product with proof of purchase to an
authorized Amprobe Service Center or to an Amprobe
dealer or distributor. See Repair Section for details. THIS
WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES
- WHETHER EXPRESS, IMPLIED OR STATUTORY - INCLUDING
IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR
PURPOSE OR MERCHANTABILITY, ARE HEREBY DISCLAIMED.
MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL,
INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR
LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some
states or countries do not allow the exclusion or limitation of
an implied warranty or of incidental or consequential damages,
this limitation of liability may not apply to you.
Repair
All Amprobe returned for warranty or non-warranty repair
or for calibration should be accompanied by the following:
your name, company’s name, address, telephone number,
and proof of purchase. Additionally, please include a brief
description of the problem or the service requested and
include the test leads with the meter. Non-warranty repair
or replacement charges should be remitted in the form of a
check, a money order, credit card with expiration date, or a
purchase order made payable to Amprobe.
In-warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery
before requesting repair. During the warranty period,
any defective test tool can be returned to your Amprobe
distributor for an exchange for the same or like product.
Please check the “Where to Buy” section on amprobe.com
for a list of distributors near you. Additionally, in the United
States and Canada, in-warranty repair and replacement units
can also be sent to an Amprobe Service Center (see address
below).
Non-warranty Repairs and Replacement – United States and
Canada
Non-warranty repairs in the United States and Canada
should be sent to an Amprobe Service Center. Call Amprobe
or inquire at your point of purchase for current repair and
replacement rates.
USA: Canada:
Amprobe Amprobe
Everett, WA 98203 Mississauga, ON L4Z 1X9
Tel: 877-AMPROBE (267-7623) Tel: 905-890-7600
Non-warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Beha-
Amprobe distributor for a nominal charge. Please check the
“Where to Buy” section on beha-amprobe.com for a list of
distributors near you.
Beha-Amprobe
Division and reg. trademark of Fluke Corp. (USA)
Germany* United Kingdom
In den Engematten 14 52 Hurricane Way
79286 Glottertal Norwich, Norfolk
Germany NR6 6JB United Kingdom
Phone: +49 (0) 7684 8009 - 0 Phone: +44 (0) 1603 25 6662
beha-amprobe.de beha-amprobe.com
The Netherlands - Headquarters**
Science Park Eindhoven 5110
5692 EC Son
The Netherlands
Phone: +31 (0) 40 267 51 00
beha-amprobe.com
*(Correspondence only – no repair or replacement avail-
able from this address. European customers please contact
your distributor.)
**single contact address in EEA Fluke Europe BV
1
Probe tip with voltage sensor, magnetic sensor
(NCV-1040-EUR only) and indication.
2
Finger guard
3
Power ON/OFF / range selection
(NCV-1030 and 1040 only)
4
Light button (NCV-1030 and 1040 only)
5
Battery cap
6
Flashlight (NCV-1030 and 1040 only)
7
Voltage range
Non-Contact Voltage Probe
1
4
5
3
7
6
2
Non-Contact Voltage Probe
CONTENTS
SYMBOLS ...................................................... 1
SAFETY INFORMATION ................................2
FEATURES .....................................................3
APPLICATIONS ..............................................3
OPERATING INSTRUCTIONS .........................4
SPECIFICATIONS ............................................6
BATTERY REPLACEMENT & CARE ................7
1
SYMBOLS
Caution! Risk of electric shock
Caution! Refer to the explanation in
this instruction sheet
Double insulated
CAT IV
Equipment is for measurements
performed at the source of a low
voltage installation (i.e. electrical
meters and measurements on primary
over current protection devices and
ripple control units)
Battery
Solid particle protection: dust tight IP6x
Liquid ingress protection: water jets IPx5
Do not dispose of this product as
unsorted municipal waste-contact a
qualified recycler
Complies with European Directives
Canadian Standards Association (NRTL/C)
Conforms to relevant Australian standards
Conforms to relevant South Korean
EMC Standards
For Use by Competent Persons
Anyone using this instrument should be
knowledgeable and trained about the risks
involved with measuring voltage, especially in an
industrial setting, and the importance of taking
safety precautions. The instrument should be
tested before and after use to ensure that it is in
good working condition.
2
SAFETY INFORMATION
 Warning
To prevent possible electrical shock, fire, or
personal injury:
If the Tester is used in a manner not specified
by the manufacturer, protection provided by
the Tester may be affected.
Test on a known live source within the rated
AC voltage range of the product both before
and after use to ensure the Tester is in good
working condition.
When using the Tester, voltage may be
present even if the tip does not glow. The
Tester indicates active voltage in the presence
of electrostatic fields of sufficient strength
generated from the source voltage. If the field
strength is low, the Tester may not provide
indication of live voltage. Lack of an indication
occurs if the Tester is unable to sense the
presence of voltage which may be influenced
by several factors including, but not limited to:
- Position of the earth conductors in the
environment under test
- Shielded wire/cables
- Thickness and type of insulation
- Distance from the voltage source
- Fully-isolated users that prevent an
effective ground
- Receptacles in recessed sockets / differences
in socket design
- Condition of the Tester and batteries
The Tester is not the appropriate tool to check
for the absence of voltage. Use a voltage
tester therefore.
Do not use the Tester if it appears damaged or
is not operating properly. Closely examine the
probe tip for cracks or breakage before use. If
in doubt, have the Tester serviced.
Do not apply more than the rated voltage as
marked on the Tester.
When operating the Tester, keep fingers
behind the finger guard.
Do not use the Tester if it is not flashing upon
power on.
Use caution with voltages above 30 V AC as a
shock hazard may exist.
Comply with local and national safety requirements.
Use proper protective equipment as required
by local or national authorities.
3
FEATURES
The Amprobe NCV-1000 series Non-Contact Voltage
(NCV) tester provides maximum safety and convenience
for detecting AC voltage without interrupting electrical
systems. Designed to conveniently fit in your shirt
pocket, the NCV-1000 series tester performs in indoor
and outdoor settings. Safety tested to the highest
category measurement, CAT IV 1000 V, as well as IP65
water and dust resistant, the NCV-1000 series is fit for
the toughest industrial applications.
Non-contact voltage detection up to 1000 V AC
Built-in flashlight (NCV-1030 and NCV-1040)
Water and dust resistant - IP65 rated
Audible (buzzer) and visual (LED) voltage indication
On/off switch
Auto power off (NCV-1030 and NCV-1040)
CAT IV 1000 V safety rated
Magnetic solenoid testing (NCV-1040)
Low battery indication (NCV-1030 and NCV-1040)
NCV-1020 NCV-1030 NCV-1040
NCV Default
range
(AC)
50 to 1000 V 50 to 1000 V 50 to 1000 V
NCV High
Sensitivity
range (AC)
12 to 50 V
*
12 to 50 V
*
Magnetic
solenoid
testing
* Note: High sensitivity range is optimized for
12 to 50 V range with a maximum indication up
to 1000 V. Using the tester above 50 V in high
sensitivity range may affect polarity indication.
Your shipping carton includes a Tester, user manual
and 2 1.5 V AAA batteries (installed).
APPLICATIONS
Detects the presence of AC voltage in cables,
circuit breakers, wall sockets, junction boxes,
fuses, extension cords and more.
Tests voltage through wire insulation.
Identifies cable breaks in wires, cords and
lighting systems connected in series.
Identifies polarity (line vs. neutral) of receptacles
and cables. (Depending of the internal
construction and dimension of receptacles in
different countries this application may be
influenced.)
Tests voltage without contact.
4
Safety CAT IV 1000 V rated for a wide range of
applications including industrial, commerical,
and residential.
Water-resistant IP65 rated for indoor and
outdoor use.
Magnetic solenoid detection to diagnose
electromagnets and relays (NCV-1040 only).
OPERATING INSTRUCTIONS
Turning the Tester ON
To turn the Tester on, momentarily press the ON/OFF
button. A continual single flash visually indicates the
Tester is active in default voltage range
(50 to 1000 V).
Press the ON/OFF button again to switch to high
sensitivity range
(12 to 50 V for NCV-1030 and NCV-1040
only).
A continual double flash indicates the Tester’s
sensitivity range is at the 12 to 50 V range.
Turning the Tester OFF
Press and hold the ON/OFF button for longer
than two second to turn the Tester off. The absence
of flash at the tip indicates the Tester is inactive.
Auto Power Off
To save battery life, the NCV-1030 and NCV-1040
are enabled with an automatic power off feature.
The Tester will automatically power off after
approximately 3 minutes of non-use.
Checking for the Presence of AC Voltage
To test for the presence of AC voltage in a
receptacle, insert the tip of the Tester. To test a
wire, approach the wire with the tip of the Tester.
Switch between default (50 V to 1000 V AC) and
high sensitivity (12 V to 50 V AC) voltage range
detection by short pressing the ON/OFF button
(NCV-1030 and 1040 only). The LED at the tip of the
Tester will illuminate solid bright red and a buzzer
will sound when AC voltage is detected. Note: High
sensitivity range is optimized for 12 to 50 V range
with a maximum indication up to 1000 V. Using
the tester above 50 V in high sensitivity range may
affect polarity indication.
When operating the Tester, keep fingers behind
the finger guard.
5
Checking for the Magnetic Field (NCV-1040)
The NCV-1040 can test for a magnetic field in
addition to AC voltage detection. A solid yellow
LED will illuminate when a magnetic field is
detected.
Note: If AC voltage and a magnetic field are
detected simultaneously, the Tester will flash both
red and yellow.
Testing receptacle:
m
LINE Contact
Testing wire and cable breaks:
LINE
Cable break
m
6
Using the Flashlight
A flashlight is installed in the NCV-1030 and NCV-1040.
Activate the flashlight by pressing the button .
To switch OFF the flashlight press the button
again.
SPECIFICATIONS
Operating
Voltage Range
NCV-1020:
50-1000 Vac, 50-400 Hz
NCV-1030:
12-50 Vac, 50-1000 Vac, 50-400 Hz
NCV-1040:
12-50 Vac, 50-1000 Vac, 50-400 Hz
Voltage
Detection
(default
range)/
sensetivity
LED and buzzer indications at
approximately 5 mm (0.20 in)
distance from a wire carrying
230 Vac
Detection of
Magnetic Field/
sensetivity
NCV-1040:
approximately >2.5 mT
Measuring
category
CAT IV 1000V
Ingress
protection
IP65
Temperature
Range
32 °F to 104 °F (0 °C to 40 °C),
≤ 80% RH
Storage
Conditions
14 °F to 104 °F (-10 °C to 40 °C),
≤ 85% RH
Operating
Altitude
≤ 6561 ft (2000 m)
Duty Cycle Continuous
Power Supply 2 x 1.5 V LR03 AAA batteries
Current
Consumption
Approximately 80 mA
Dimensions
(L x W x H)
6.14 x 0.92 x 1.08 in
(156.2 x 23.5 x 27.5 mm)
Weight
(with batteries
installed)
NCV-1020: Approx. 0.12 lb (58 g)
NCV-1030: Approx. 0.13 lb (60 g)
NCV-1040: Approx. 0.136 lb (62 g)
Safety
Compliance
IEC 61010-1 3rd Ed., UL 61010-1 3rd
Ed., UL 61010-2-030, CAN/CSA-C22.2
No.61010-1-12, CAN/CSA-C22.2 No.
61010-2-030-12 to CAT IV 1000 V,
Pollution degree 2, IP65
7
EMC
Compliance
IEC 61326-1
Korea (KCC): Class A Equipment
(Industrial Broadcasting &
Communication Equipment)
[1]
[1]
This product meets requirements
for industrial (Class A) electromagnetic
wave equipment and the seller or
user should take notice of it. This
equipment is intended for use in
business environments and is not to
be used in homes.
Certifications
BATTERY REPLACEMENT & CARE
Low Battery Indication
The NCV-1030 and NCV-1040 Testers provide a low
battery indication in the form of a slowly blinking
red LED upon power on when battery level is low
and the batteries should be replaced. At that point
no voltage indication is possible.
The NCV-1020 does not provide the same
indication; instead, batteries will need to be
replaced when no LED appears upon power on.
Battery Replacement
To remove the battery cap, use the thumb grip to
pull it upwards and outwards. Remove batteries
and replace with (2) AAA 1.5 V alkaline batteries,
noting the battery orientation as shown on the
side of the tester. Replace the cap.
If the Tester will not be used for a long period
of time, remove the batteries.
Cleaning
The Tester can be cleaned with a mild solution of
soapy water. Apply sparingly with a soft cloth and
allow to dry completely before using. Do not use
aromatic hydrocarbons, gasoline, or chlorinated
solvents for cleaning.
Battery Cap
Latch
7
Série NCV-1000
Sonde de tension sans
contact
Manuel de l’utilisateur
7/2018, 6009474 Rev B
©2018 Amprobe
Tous droits réservés. Imprimé en Chine
Français
Garantie limitée et limitation de responsabilité
Votre produit Amprobe sera exempt de défauts de
matériaux et de fabrication pendant un (1) an à compter
de la date d'achat, sauf exigence contraire en vertu de
la juridiction locale. Cette garantie ne s'applique pas aux
fusibles, aux piles jetables ou endommagées par accident,
à la négligence, à la mauvaise utilisation, à l'altération, à
la contamination ou aux conditions anormales d'utilisation
ou de manipulation. Les revendeurs ne sont pas autorisés
à prolonger toute autre garantie au nom de Amprobe.
Pour une réparation au cours de la période de garantie,
retournez le produit avec la preuve d'achat à un centre
de service autorisé par Amprobe ou à un revendeur ou
un distributeur Amprobe. Voir la section Réparation
pour plus de détails. CETTE GARANTIE EST VOTRE SEUL
RECOURS. TOUTES LES AUTRES GARANTIES – QU'ELLES
SOIENT EXPLICITES, IMPLICITES OU JURIDIQUES – Y
COMPRIS LES GARANTIES IMPLICITES D'ADAPTATION À UN
USAGE PARTICULIER OU MARCHAND, SONT EXCLUES. LE
FABRICANT NE SERA PAS RESPONSABLE DES DOMMAGES
SPECIAUX, INDIRECTS, ACCESSOIRES OU CONSECUTIFS
PROVENANT DE TOUTE CAUSE OU THEORIE. Etant donné
que certains pays ou états n'autorisent pas l'exclusion ou la
limitation des garanties implicites ou des dommages directs
ou indirects, cette limitation de responsabilité peut ne pas
s'appliquer à vous.
Réparation
Tout produit Amprobe retourné pour réparation sous
garantie ou hors garantie ou pour l'étalonnage doit être
accompagné des documents suivants:votre nom, le nom
de votre société, votre adresse, votre numéro de téléphone
et la preuve d'achat. De plus, veuillez inclure une brève
description du problème ou du service demandé et
incluez les cordons de mesure avec le compteur. Les frais
de réparation ou de remplacement non garantis doivent
être réglés sous forme de chèque, mandat, carte de crédit
avec date d'expiration ou bon de commande payable à
Amprobe.
Réparation et remplacement couverts par la garantie –
Tous les pays
Veuillez lire la déclaration de garantie et vérifier la pile
avant de demander une réparation. Pendant la période de
garantie, tout outil de vérification défectueux peut être
retourné à votre distributeur Amprobe pour un échange de
produit identique ou similaire. Veuillez consulter la section
«Où acheter» sur le site amprobe.com pour obtenir une
liste des distributeurs près de chez vous. En outre, aux
États-Unis et au Canada, les réparations sous garantie et les
unités de remplacement peuvent également être envoyés à
un centre de service Amprobe (voir adresse ci-dessous).
Réparation et remplacement non couverts par la garantie –
États-Unis et Canada
Pour les réparations non couvertes par la garantie aux
États-Unis et au Canada, l'appareil doit être envoyé à
un centre de service Amprobe. Appelez Amprobe ou
renseignez-vous auprès de votre point de vente pour les
tarifs de réparation et de remplacement actuels.
États-Unis: Canada:
Amprobe Amprobe
Everett, WA 98203 Mississauga, ON L4Z 1X9
Tél.: 877-AMPROBE (267-7623) Tél.: 905-890-7600
Réparation et remplacement non couverts par la garantie
– Europe
Les unités hors garantie européenne peuvent être
remplacées par votre distributeur Amprobe/Beha-Amprobe
pour une somme modique. Veuillez consulter la section
«Où acheter» sur le site beha-amprobe.com pour obtenir
une liste des distributeurs près de chez vous.
Beha-Amprobe
Division et marque déposée de Fluke Corp. (USA)
Allemagne* Royaume-Uni
In den Engematten 14 52 Hurricane Way
79286 Glottertal Norwich, Norfolk
Germany NR6 6JB United Kingdom
Télé : +49 (0) 7684 8009 - 0 Tél : +44 (0) 1603 25 6662
beha-amprobe.de beha-amprobe.com
Pays-Bas - Siège social**
Science Park Eindhoven 5110
5692 EC Son
Pays-Bas
Tél : +31 (0) 40 267 51 00
beha-amprobe.com
*(Correspondance uniquement: aucune réparation ou
remplacement à cette adresse. Clients européens, veuillez
contacter votre distributeur.)
**adresse de contact unique dans l'EEE Fluke Europe BV
1
Pointe de sonde avec capteur de tension,
capteur magnétique (NCV-1040-EUR
uniquement) et indication.
2
Protège-doigts
3
Mise sous/hors tension / sélection de la plage
(NCV-1030 et 1040 uniquement)
4
Bouton Lampe (NCV-1030 et 1040
uniquement)
5
Couvercle des piles
6
Lampe de poche (NCV-1030 et 1040
uniquement)
7
Plage de tensions
Sonde de tension sans contact
1
4
5
3
7
6
2
Sonde de tension sans contact
TABLE DES MATIÈRES
SYMBOLES .................................................... 1
INFORMATIONS DE SÉCURITÉ .....................2
CARACTÉRISTIQUES ....................................3
APPLICATIONS ..............................................3
CONSIGNES D'UTILISATION .........................4
SPÉCIFICATIONS ............................................6
REMPLACEMENT ET ENTRETIEN DES PILES .7
SYMBOLES
Attention! Risque de choc électrique
Attention! Reportez-vous aux
explications de ce mode d'emploi
Double isolation
CAT IV
Cet équipement est destiné à des
mesures effectuées à la source d'une
installation basse tension (à savoir
compteurs et mesures électriques sur
des dispositifs principaux de protection
contre les surintensités et des unités de
commande centralisées)
Pile
Protection contre les particules solides :
étanchéité à la poussière IP6x
Protection contre la pénétration de
liquides : projections d'eau IPx5
Ne jetez pas ce produit avec les déchets
municipaux non triés : contactez un
recycleur qualifié
Conforme aux directives européennes.
Association canadienne de
normalisation (NRTL/C)
Conforme aux normes australiennes
pertinentes.
Conforme aux normes relatives aux
CEM applicables en Corée du Sud
Pour une utilisation par des personnes
compétentes
Toute personne utilisant cet instrument doit
être renseignée et formée aux risques associés
à la mesure de la tension, en particulier dans un
environnement industriel, et l'importance de
prendre des mesures de sécurité. L'instrument doit
être testé avant et après utilisation pour s'assurer
qu'il est en bon état de fonctionnement.
1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Amprobe NCV-1020, NCV-1030 & NCV-1040 Manuel utilisateur

Taper
Manuel utilisateur