NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
This wood appliance needs periodic inspection and repair for proper operation. It is against United States federal
regulation to operate this wood appliance in a manner inconsistent with operating instructions in this manual.
INSTALLATION AND
OPERATING INSTRUCTIONS
1.27D
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)720-9081 • www.napoleonfi replaces.com • hearth@napoleonproducts.com
SAFETY INFORMATION
!
WARNING
If the information in these instructions is not followed exactly, a
re or explosion may result causing property damage, personal
injury or death. Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage,
bodily injury or even death. Please read entire manual before
you install and use your appliance.
This appliance has not been tested with an unvented gas log
set. To reduce risk of fi re or injury, do not install an unvented
gas log set into the appliance.
- This appliance can be very hot when burning.
- Combustible materials such as fi rewood, wet clothing, etc. placed too close
can catch fi re.
-
Children and pets must be kept from touching the appliance when it is hot.
-
The chimney must be sound and free of cracks. Before installing this unit,
contact the local building or fi
re authority and follow their guidelines.
- Operate only with the door tightly closed.
-
Burn wood behind the log r
etainer directly on the fi rebricks.
-
Do not use an elevated grate or otherwise raise the fi
re.
-
At least 14 square inches (90.3 square centimeters) of outside air must be
admitted to the room or dir
ectly to the unit through a 4” (101.6mm) diameter
pipe.
- This appliance is designed to burn natural wood only. Higher effi ciencies and
lower emissions generally result when burning air dried seasoned hardwoods,
as compared to softwoods or to green or freshly cut hardwoods.
-
Do not start a fi
re with chemicals or fl uids such as gasoline, engine oil, etc.
- Do not burn trash or garbage, lawn clippings / waste, rubber, waste petroleum
products, paints or paint thinners / solvents, plastic, materials containing
asbestos, construction debris, railroad ties or treated wood, manure or animal
remains, salt water driftwood or salted materials, unseasoned wood, coal,
charcoal, coloured paper, cardboard, plywood or particleboard.
- Do not let the appliance become hot enough for any part to glow red.
- KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to
achieve heat output rates that exceed design specifi cations can result in steel
distortion and damage.
$10.00
LA VITRE CHAUDE CAUSERA
DES BRÛLURES.
NE PAS TOUCHER LA VITRE
AVANT QU’ELLE AIT REFROIDI.
NE JAMAIS LAISSER LES
ENFANTS TOUCHER LA VITRE.
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
!
AVERTISSEMENT
MODEL 1101 & 1402 MEET THE 2015 U.S ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) CRIB WOOD EMISSION LIMITS FOR WOOD STOVES SOLD AFTER MAY
15, 2015, 40 C.F. R. PART 60. THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS:
ULC S628, UL 1482.
EPI 1101 & 1402
WOOD INSERT
1402 Illustrated
W415-1469 / C / 08.20.18
2
EN
NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.
TABLE OF CONTENTS
1.0 INSTALLATION OVERVIEW 3
2.0 INTRODUCTION 4
2.1 DIMENSIONS 5
2.1.1 1101 DIMENSIONS (COMPLETE WITH FLASHING) 5
2.1.2 1402 DIMENSIONS (COMPLETE WITH FLASHING) 5
2.2 SPECIFICATIONS 5
2.3 GENERAL INSTRUCTIONS 6
2.4 GENERAL INFORMATION 6
2.5 RATING PLATE INFORMATION 8
3.0 INSTALLATION PLANNING 9
3.1 MINIMUM CLEARANCE TO COMBUSTIBLES 9
4.0 INSTALLATION 10
4.1 TYPICAL EXISTING MASONRY 11
4.2 FACTORY BUILT FIREPLACE 12
4.3 LOW CLEARANCE FLUE CONNECTOR (1402) 12
5.0 FINISHING 13
5.1 BRICKS AND BAFFLES INSTALLATION 13
5.2 DOOR REMOVAL / INSTALLATION 14
5.3 DOOR HANDLE INSTALLATION 14
5.4 FLASHING INSTALLATION 15
6.0 OPERATION 16
6.1 OPTIMUM BURN METHOD 17
6.2 BLOWER 18
6.3 AIR CONTROL 18
6.4 FIRE EXTINGUISHERS / SMOKE & CARBON MONOXIDE DETECTORS 18
6.5 FUEL 19
6.6 LIGHTING A FIRE 20
6.6.1 FLASH FIRE 20
6.6.2 EXTENDED FIRE 20
6.7 SMOKING 20
7.0 MAINTENANCE 21
7.1 ASH REMOVAL PROCEDURES 21
7.2 CREOSOTE FORMATION AND REMOVAL 21
7.3 RUNAWAY OR CHIMNEY FIRE 22
7.4 CHIMNEY CLEANING 22
7.5 GLASS REPLACEMENT 23
7.6 GASKET REPLACEMENT 23
7.7 SECONDARY AIR MANIFOLD REPLACEMENT 24
7.8 CARE OF GLASS 25
7.9 CARE OF PLATED PARTS 25
7.10 BLOWER SERVICE OR REPLACEMENT (1402) 26
7.11 BLOWER SERVICE OR REPLACEMENT (1101) 27
8.0 REPLACEMENTS 27
8.1 EPI-1402 OVERVIEW 28
8.2 EPI-1101 OVERVIEW 29
9.0 ACCESSORIES 30
10.0 TROUBLESHOOTING 31
11.0 WARRANTY 32
12.0 SERVICE HISTORY 33
W415-1469 / C / 08.20.18
3
EN
Rating plate, see
“RATING PLATE
INFORMATION”
section.
Blower, see “BLOWER INSTALLATION”
section.
Door, see “DOOR AND
HANDLE INSTALLATION”
section.
Flashing, see “FLASHING
INSTALLATION” section.
Draft, see “AIR CONTROL” section.
Brick and Baffles, see
“BRICK AND BAFFLES
INSTALLATION” section.
1.0 INSTALLATION OVERVIEW
1402 Illustrated
W415-1469 / C / 08.20.18
4
EN
2.0 INTRODUCTION
3.17G
!
WARNING
THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.
ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND
IS PROHIBITED.
Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance
according to operating instructions could cause fi re or injury.
Before installing this appliance, contact the local building or fi re authority and follow their guidelines.
This appliance must be installed by a qualifi ed installer.
Risk of burns. The appliance should be turned off and cooled before servicing.
Do not operate without fully assembling all components.
Do not let the appliance become hot enough for any part to glow red.
Do not install damaged, incomplete or substitute components.
Risk of cuts and abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges may
be sharp.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid
burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young
children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there
are at risk individuals in the house. To restrict access to an appliance or stove, install an adjustable safety gate to
keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
Clothing or other fl ammable material should not be placed on or near the appliance. Objects placed in front of the
appliance must be kept a minimum of 4 feet (1.2m) away from the front face of the appliance.
Due to high temperatures, the appliance should be located out of traffi c and away from furniture and draperies.
Ensure you have incorporated adequate safety measures to protect infants/toddlers from touching hot surfaces.
Even after the appliance is out, the glass and / or screen will remain hot for an extended period of time.
Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot
surfaces. These screens and guards must be fastened to the fl oor.
Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
Under no circumstances should this appliance be modifi ed.
This appliance must not be connected to a chimney fl ue pipe servicing a separate solid fuel burning appliance.
Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the glass should
be done by a licensed or qualifi ed service person.
Do not strike or slam shut the appliance glass door.
Only doors / optional fronts certifi ed with the appliance are to be installed on the appliance.
Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with all
plastic bags, these are not toys and should be kept away from children and infants.
If the appliance is not properly installed, a house fi re may result. Do not expose the appliance to the elements (ex.
rain, etc.) and keep the appliance dry at all times. Wet insulation will produce an odour when the appliance is used.
The chimney must be sound and free of cracks. Clean your chimney a minimum of twice a year and as required.
Do not start a fi re with chemicals or fl uids such as gasoline, engine oil, etc.
Your appliance requires periodic maintenance and cleaning. Failure to maintain your appliance may lead to smoke
spillage in your home.
Lower emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods or too
green or freshly cut hardwoods. Burning wet unseasoned wood can cause excessive creosote accumulation.
When this is ignited it can cause a chimney fi re that may result in a serious house fi re.
This appliance is designed to burn natural wood only. Do not burn trash or garbage, lawn clippings / waste,
rubber, waste petroleum products, paints or paint thinners / solvents, plastic, materials containing asbestos,
construction debris, railroad ties or treated wood, manure or animal remains, salt water driftwood or salted
materials, unseasoned wood, coal, charcoal, coloured paper, gift wrapping, cardboard, plywood or particleboard.
Burning these materials may result in release of toxic fumes or render the appliance ineffective and cause smoke.
Burn wood directly on the fi rebricks. Do not elevate grate or otherwise raise the fi re.
Do not store wood within appliance installation clearances or within the space required for re-fueling and ash removal.
Ashes must be disposed in a metal container with a tight lid and placed on a non-combustible surface well away
from the home or structure until completely cool.
Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance.
Elevated temperatures on the wall or in the air above the appliance can cause melting, discolouration or damage to
decorations, a T.V. or other electronic components.
If equipped, the catalyst must be installed and in good working order. It is recommended that the catalyst is
inspected at least 3 times per heating season.
W415-1469 / C / 08.20.18
5
EN
* As tested using test method 28
** Figures will vary considerably with individual conditions.
***Wolf Steel Ltd. estimated realistic BTU/hr with hardwood logs and regular refueling.
Specifications 1101 1402
CHAMBER (D.W.H) 13 1/2x18x12" (343mmx-
457mmx305mm)
18x18x12" (457mmx457mmx-
305mm)
CAPACITY 1.7 ft
3
2.25 ft
3
APPROX. AREA HEATED** 600-1600 ft
2
800-2000 ft
2
MAXIMUM HEAT OUTPUT*** 55,000 BTU/Hr 70,000 BTU/Hr
HEAT OUTPUT* 11,700 - 42,200 BTU/Hr 11,400 - 41,300 BTU/Hr
DURATION LOW FIRE** 7 Hours 9 Hours
WEIGHT W/O BRICKS 185 lbs (84kg) 250 lbs (113kg)
WEIGHT OF BRICKS 110 lbs (50kg) 145 lbs (66kg)
IDEAL FUEL SIZE 12" (305mm) 16" (406mm)
MINIMUM DEPTH 16 1/2" (419mm) 14" (356mm)
MAXIMUM DEPTH 21" (533mm) 14" (356mm)
2.1 DIMENSIONS
2.1.1 1101 DIMENSIONS (COMPLETE WITH FLASHING)
2.1.2 1402 DIMENSIONS (COMPLETE WITH FLASHING)
44 1/2"
1130mm
19 3/4"
502mm
31 3/4"
806mm
21 1/2"
546mm
20 3/4"
527mm
14"
356mm
9 1/16"
231mm
24 1/2"
622mm
25 1/2"
648mm
5 1/2"
139mm
25 1/2"
648mm
21 11/16"
551mm
20 1/2"
521mm
31 3/4"
806mm
44 1/2"
1130mm
21 1/4"
540mm
16 1/2"
419mm
-
21"
533mm
28"
711mm
24"
610mm
11"
279mm
25 1/2"
648mm
21 11/16"
551mm
20 1/2"
521mm
2.2 SPECIFICATIONS
W415-1469 / C / 08.20.18
6
EN
2.3 GENERAL INSTRUCTIONS
Before beginning your installation, consult with your local building code agency or fire officials and insur-
ance representative to ensure compliance.
Non-toxic smoke will be emitted during the paint curing process, to help dissipate the smoke open a
window near the appliance.
Remove any dust or debris off the top of the appliance before firing the appliance as the paint will become
soft as the appliance heats up and will harden as the appliance cures. To cure the paint on your appliance
burn your appliance moderately hot during the first few fires.
To keep the gasket from sticking to the appliance as the paint is curing, periodically open the door every
5-10 minutes.
For the first two weeks, use generous amounts of fuel and burn the appliance with the damper wide open
for an hour as the appliance goes through a process of eliminating moisture in the steel and firebricks.
The initial heat output will be reduced while the moisture is bring drawn from the appliance and it will
be necessary to build several hot fires to remove this moisture. DURING THIS PROCESS DO NOT
OVERFIRE THE APPLIANCE. REDUCE THE AMOUNT OF AIR COMING INTO THE APPLIANCE IF
THE APPLIANCE OR CHIMNEY BECOMES RED.
4.7
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH
LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIAN
ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI/NFPA NO. 70 IN
THE UNITED STATES.
THIS APPLIANCE HAS NOT BEEN TESTED WITH ANY VENTED OR UNVENTED GAS LOG SET. TO
REDUCE RISK OF FIRE OR PREVENT INJURY, DO NOT INSTALL A VENTED OR UNVENTED GAS LOG
SET INTO THE APPLIANCE.
BURNING YOUR UNIT WITH THE ASH DUMP DOOR OPEN OR AJAR CREATES A FIRE HAZARD THAT
MAY RESULT IN DISCOLOURATION TO THE GOLD PLATED DOOR, INTERNAL DAMAGE TO THE
APPLIANCE OR A HOUSE CHIMNEY FIRE.
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
THIS APPLIANCE AND IT’S COMPONENTS ARE DESIGNED TO BE INSTALLED AND OPERATED AS A
SYSTEM. ANY ALTERATION TO OR SUBSTITUTION FOR ITEMS IN THIS SYSTEM, UNLESS ALLOWED
BY THESE INSTALLATION INSTRUCTIONS, WILL VOID THE LISTING AND MAY VOID THE PRODUCT
WARRANTY. IT MAY ALSO CREATE A HAZARDOUS INSTALLATION. READ THROUGH THESE
INSTRUCTIONS THOROUGHLY BEFORE STARTING YOUR INSTALLATION AND FOLLOW THEM
CAREFULLY THROUGHOUT YOUR PROJECT.
!
WARNING
Your appliance was specifically designed to meet the 1990 U.S.A. EPA particulate emission standards and has
been extensively tested in Canadian and American laboratories. This system is the most efficient, simple and
trouble free we know and works as follows:
Your appliance is the exact duplication of the clean-burning technology found in all Napoleon EPA certified freestanding
stoves and in particular that of the EPA 1100 and 1400. External modifications have been made to allow its installation as a
“functional insert” with a heat circulating blower system and a means of enclosing the solid fuel burning fireplace cavity for
greater heating efficiency.
2.4 GENERAL INFORMATION
W415-1469 / C / 08.20.18
7
EN
The 1101 insert must be installed into a solid fuel burning fireplace that is at least 16 1/2” (419mm) deep, 28 1/2" (724mm)
wide and 22" (559mm) high with an approved lined chimney at least 15' (4.6m) high and a hearth of 16” (406mm).
Your 1402 insert must be installed only into a solid fuel burning fireplace that is at least 14" (356mm) deep, 26" (660mm)
wide and 22" (559mm) high with an approved lined chimney at least 15' (4.6m) high and a hearth of 16” (406mm). This
minimum recess can only be achieved if the opening height is sufficient enough to allow the connector to fit under the
non-combustible facing. The appliance and chimney must be constructed in accordance with all national and local building
code standards.
The chimney vent system used on your wood burning appliance should be designed with the least amount of restriction
possible to enable the exhaust products to easily flow through it. Chimney vent systems that are too short or too long
can also have an adverse affect on the flow of exhaust through it. The wood burning appliance and chimney vent
system also require a sufficient supply of combustion air not only to support the combustion in the combustion chamber
but to replace the exhaust leaving it so it can flow freely up through the vent system and out into the atmosphere. It is
the correct balance of combustion air and the chimney vent system that will ensure the appliance provides you with its
optimum performance.
Combustion air enters through two holes in the bottom covered by a single draft control. Air from the front hole
goes up on either side of the door into a preheating
airwash located across the top and then down the
window to feed the fire and also to ensure that the glass
remains clean. Air from this hole also feeds directly into
the combustion chamber at hearth level. Secondary air
from the rear hole travels up the back in the secondary air
housing to the manifold located at the top and shoots out
laterally to oxidize the gases below the smoke exit.
The combustion chamber is lined with high temperature
firebrick on 2 sides, the back and across the bottom,
with a layer of fibre baffles at the top to maintain a high
temperature in the combustion chamber so that gases
mixing with the preheated air from the secondary air
manifold tube are easily ignited and burned. The appliance
sides and back are shielded to direct the heat upwards
and forwards into the room.
Be sure to provide sufficient combustion air. There are
many other appliances in your home competing for air
such as: a kitchen range hood, forced air heating devices
or a bathroom exhaust fan.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
After extended periods of non-operation such as following a vacation or a warm weather season, the appliance
may emit a slight odour for a few hours. This is
caused by dust particles on the firebox burning off.
Open a window to sufficiently ventilate the room.
If you experience smoking problems, you may
need to open a door, a window or otherwise
provide some method of supplying combustion air to the appliance.
HINT FOR INSTALLING PORCELAIN ENAMEL INSERTS:
Ensure the base of the porcelain side panels are protected from rubbing against the hearth when sliding your
insert into the masonry fireplace.
HOT SECONDARY AIR
FIBRE BRICKS
REFRACTORY
2 SIDES, BACK
& BOTTOM
SECONDARY AIR
PRIMARY AIR
FLUE GLASS
CERAMIC
GLASS
AIR CONTROL
COMBUSTION AIR
INTAKE
OPEN
CLOSED
We suggest that our woodburning hearth products
be installed and serviced by professionals who are
certified in the U.S. by the National Fireplace
Institute® (NFI) as NFI Woodburning Specialists or
who are certified in Canada by
Wood Energy Technical
Training (WETT).
W415-1469 / C / 08.20.18
8
EN
2.5 RATING PLATE INFORMATION
WOLF STEEL LTD
TITLE: RATING PLATE LABEL EPA1400
REVISION: B
DRAWN BY: J.K.
CHECKED BY: 11.08.16_C.L.
MATERIAL:
CLASS III A-2 PERMANENT LABEL
MM/DD/YY: 11.08.16
MODEL: S4, 1400, 1400L, 1402, 1450, 1400C
DRAWING: W385-2031
FINISH:
MM/DD/YY: 03.18.16
SHEET 1 0F 1
MAXIMUM SIZE: 6" x 11.250"
SILVER ON BLACK BACKGROUND
SPECIFICATIONS: WATERPROOF, NONWATER SOLUBLE ADHESIVE CAPABLE OF WITHSTANDING A MAXIMUM
TEMPERATURE OF 175°F (79°C).
SERIAL NUMBER TO BE ASCENDING FROM EPA1400
117839
CAUTION MINIMUM LETTER SIZE (18 POINT TYPE) AND 0.12" (8.64 POINT TYPE) FOR THE REMAINDER OF
THAT WARNING WITH VERTICAL SPACING BETWEEN LINES OF 0.046" (3.312 POINT TYPE).
LOG / FIRE WARNING SYMBOL TO BE RED
LISTED SOLID FUEL BURNING FIREPLACE INSERT /
ENCASTRÉ À COMBUSTIBLE SOLIDE HOMOLOGUÉ
TESTED TO / TESTÉ SELON :
ULC S628 / UL 1482
FROM HEATER / DU POÊLE
RESIDENTIAL / RÉSIDENTIEL
S4
16IN/PO (406 mm)
12IN/PO (305 mm)
6IN/PO (152 mm)
USING DOUBLE WALL CONNECTOR /
UTILISATION D’UN CONDUIT DE
RACCORDEMENT À DOUBLE PAROI
MAISON / MOBILE HOME
*
S4
1400
16IN/PO (406 mm)
10IN/PO (254 mm)
6IN/PO (152 mm)
6IN/PO (152 mm)
4IN/PO (102 mm)
4IN/PO (102 mm)
EPI 1402
INSTALL AND USE ONLY IN
ACCORDANCE WITH THE
MANUFACTURER’S
INSTRUCTIONS AND LOCAL
BUILDING CODES.
MINIMUM CEILING HEIGHT:
7FT (2.13m)
HEARTH EXTENSION /
COMBUSTIBLE FLOOR
PROTECTION: IF INSTALLED
ON A COMBUSTIBLE FLOOR,
APPLIANCE MUST BE PLACED
ON A NON-COMBUSTIBLE
FLOOR PROTECTOR
EXTENDING 18” (455mm) IN
FRONT AND 8” (205mm) TO
THE SIDES AND BACK.
CHIMNEY TYPE: MINIMUM 6”
(152mm) DIAMETER
APPROVED RESIDENTIAL
TYPE FOR MOBILE HOME USE
A CHIMNEY LISTED TO ULC
S629 IN CANADA OR UL 103HT
IN THE USA.
CHIMNEY CONNECTOR: 6”
(152mm) DIAMETER MINIMUM
24 GAUGE STEEL MINIMUM
CLEARANCE FROM
HORIZONTAL CONNECTOR
AND CEILING 18” (455mm).
DO NOT OBSTRUCT SPACE
UNDER APPLIANCE.
SPECIAL METHODS ARE
REQUIRED WHEN PASSING A
CHIMNEY THROUGH A WALL
OR CEILING. SEE INSTRUC-
TIONS AND BUILDING CODES.
DO NOT CONNECT THIS
APPLIANCE TO A CHIMNEY
FLUE SERVING ANOTHER
APPLIANCE.
FUEL: FOR USE WITH WOOD
ONLY. DO NOT USE GRATE OR
ELEVATE FIRE. BUILD WOOD
FIRE DIRECTLY ON HEARTH.
WARNING: RISK OF SMOKE
SPILLAGE. OPERATE ONLY
WITH DOOR FULLY CLOSED.
REPLACE GLASS ONLY WITH
CERAMIC GLASS.
DO NOT OVERFIRE. IF
APPLIANCE OR CHIMNEY
CONNECTORS GLOW, YOU
ARE OVERFIRING. INSPECT
AND CLEAN CHIMNEY
FREQUENTLY. UNDER
CERTAIN CONDITIONS OF
USE CREOSOTE BUILD-UP
MAY OCCUR RAPIDLY.
OPTIONAL BLOWER KIT:
EP-62, 115V, 60HZ, 0.82AMP.
ROUTE CORD AWAY FROM
APPLIANCE.
DANGER: RISK OF
ELECTRICAL SHOCK.
DISCONNECT POWER
BEFORE SERVICING
APPLIANCE.
INSERT: INSTALL AND USE
ONLY IN SOLID FUEL
BURNING FIREPLACES. DO
NOT REMOVE BRICKS OR
MORTAR FROM SOLID FUEL
BURNING FIREPLACE.
INSTALL WITH A POSITIVE
FLUE CONNECTOR AND
FACEPLATE.
POUR INSTALLATION ET
UTILISATION CONFORM
ÉMENT AUX
INSTRUCTIONS DU FABRICANT ET
AUX CODES LOCAUX DU BÂTIMENT.
HAUTEUR DE PLAFOND MINIMAL
7PI (2,13m).
PROLONGEMENT
D’ÂTRE/PROTECTION DU
PLANCHER COMBUSTIBLE: SI
INSTALLÉ SUR UN PLANCHER
COMBUSTIBLE, L’APPAREIL DOIT
ÊTRE PLACÉ SUR UNE PLAQUE
PROTECTRICE INCOMBUSTIBLE
S’ÉTENDANT SUR 18” (455mm)
À
L’AVANT ET 8” (205mm) À L’ARRIÈRE
ET SUR LES CÔTÉS.
TYPE DE CHIMNÉE: DIAMÈTRE
MINIMAL DE 6” (152mm)
APPROUVÉE POUR USAGE
RÉSIDENTIEL. MAISON MOBILE
EMPLOYEZ UNE CHEMINÉE
HOMOLOGUÉE ULC S629 AU
CANADA OU UL 103HT AUX
ÉTATS-UNIS.
RACCORD DE CHEMINÉE:
DIAMÈTRE DE 6” (152mm) D’ACIER
DE CALIBRE 24 MINIMUM. 18”
(455mm) DE DÉGAGEMENT MINIMAL
ENTRE LE RACCORD HORIZONTAL
ET LE PLAFOND.
NE RIEN ENTREPOSER SOUS
L’APPAREIL.
DES MÉTHODES SPÉCIALES SONT
REQUISES LORSQU’UNE CHEMINÉE
TRAVERSE UN MUR OU UN
PLAFOND. VOIR LES INSTRUC-
TIONS ET LES CODES DU
BÂTIMENT.
NE PAS RACCORDER À LA
CHEMINÉE D’UN AUTRE APPAREIL.
COMBUSTIBLE: POUR USAGE AVEC
LE BOIS SEULEMENT. N’UTILISEZ
PAS DE CHENET OU NE
SURÉLEVEZ PAS LE BOIS.
PRÉPAREZ LE FEU DIRECTEMENT
SUR L’ÂTRE.
AVERTISSEMENT: RISQUE
D’ÉCHAPPEMENT DE FUMÉE. TENIR
LA PORTE FERMÉE LORSQUE LE
POÊLE FONCTIONNE. REMPLACEZ
LA VITRE PAR UNE VITRE EN
CÉRAMIQUE SEULEMENT.
NE SURCHAUFFEZ PAS L’APPAREIL.
SI L’APPAREIL OU LES RACCORDS
ROUGEOIENT, L’APPAREIL
SURCHAUFEE. INSPECTEZ ET
NETTOYEZ LA CHEMINÉE
FRÉQUEMMENT. DANS CERTAINES
CONDITIONS, DES DÉPÔTS DE
CRÉOSOTE PEUVENT SE FORMER
RAPIDEMENT.
SOUFFLERIE OPTIONNELLE: EP-62,
115V, 60HZ, 0,82A. TENEZ LE
CORDON ÉLECTRIQUE LOIN DE
L’APPAREIL.
DANGER: RISQUE DE SECOUSSE
ÉLECTRIQUE. DÉBRANCHEZ AVANT
DE PROCÉDER À L’ENTRETIEN.
ENCASTRÉ: INSTALLEZ ET UTILISEZ
SEULEMENT DANS UN FOYER À
COMBUSTIBLE SOLIDE. NE RETIREZ
PAS DE MORTIER, NI BRIQUES DU
FOYER À COMBUSTIBLE SOLIDE.
INSTALLEZ AVEC UNE GAINE
CONFORME ET UNE PLAQUE DE
RECOUVREMENT.
CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA. MODEL 1400 IS SUITABLE FOR USE
IN MOBILE HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT (111KT).
A MINIMUM CLEARANCE OF 18” (457mm) TO THE CHIMNEY CONNECTOR MAY
BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
RENSEIGNEZ-VOUS AUPR
ÈS DES AUTORITÉS LOCALES DU BÂTIMENT ET DU
SERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONS
D’INSTALLATION DANS VOTRE RÉGION. LES MODÈLES 1400 PEUVENT ÊTRE
INSTALLÉS DANS UNE MAISON MOBILE SI INSTALLÉS CONJOINTEMENTAVEC UNE
PRISE D’AIR EXTÉRIEUR (111KT). UN DÉGAGEMENT MINIMAL DE 18” (457mm)
JUSQU’AU RACCORD DE LA CHEMINÉE PEUT ÊTRE EXIGÉ PAR L’AUTORITÉ AYANT
JURIDICTION.
8"
8"
18"
8"
ALCOVE
A"
B"
C
BACK WALL (M/A)
45°
SIDE WALL (M/L)
BACK WALL (M/A)
SIDE WALL (M/L)
B
A
IF THE STOVE IS TO BE INSTALLED ON A COMBUSTIBLE FLOOR, IT MUST BE
PLACED ON AN APPROVED NON-COMBUSTIBLE HEARTH PAD, THAT
EXTENDS 8” (200mm) BEYOND THE STOVE SIDES AND BACK, AND 18”
(455mm) TO THE FRONT.
SI LE PO
Ê
LE EST INSTALL
É SUR UN PLANCHER COMBUSTIBLE, IL DOIT ÊTRE PLACÉ
SUR UNE BASE DE PROTECTION INCOMBUSTIBLE CERTIFÉE QUI DOIT DÉPASSER
LES CÔTÉS ET L’AMÉRE DU
PO
Ê
LE DE 8” (200mm) ET SE PROLONGER DE 18”
(455mm) SUR LE DEVANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL WITH SINGLE WALL
CHIMNEY CONNECTOR / D
ÉGAGEMENTS MINIMAUX AUX MATÉRIAUX
COMBUSTIBLES AVEC RACCORD DE CHEMINÉE À PAROI SIMPLE:
*
ONLY MODELS 1400 AND S4 MAYBE INSTALLED INTO A MOBILE HOME OR
COMBUSTIBLE ALCOVE USING LISTED DOUBLE WALL CONNECTOR. MODELS
1400 AND S4 MAY BE INSTALLED INTO A MOBILE HOME IN THE UNITED
STATES ONLY.
*
LE MODÈLES 1400 ET S4 NE PEUT ÊTRE INSTALLÉ QUE DANS UNE MAISON
MOBILE AUX ÉTATS-UNIS SEULEMENT.
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS.
QUAND L’APPAREIL FONCTIONNE, LA SURFACE DEVIENT
CHAUDE. NE PAS TOUCHER. TENIR LES ENFANTS, LES
VÊTEMENTS ET LES MEUBLES À L’ÉCART. LE CONTACT PEUT
CAUSER DES BRÛLURES À LA PEAU.
CAUTION:
ATTENTION:
W385-2031 / B
EPA1400
1400 1400L 1402
1450
S4
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
1400C
9700539 (WSL)
4001657 (NGZ)
4001658 (NAC)
4001659 (WUSA)
LISTED SOLID FUEL BURNING SPACE HEATER / POÊLE À COMBUSTIBLE SOLIDE
HOMOLOGUÉ TESTED TO: / TESTÉ SELON : UL1482 / ULC S627
MODEL / MODÈLE - EPA 1400
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2015 particulate emissions standards. Not approved for sale
after May 15, 2020. Certifié conforme à la norme d’ émanation de particles de 2020. Non approuvé pour la vente après le 15 mai, 2020.
40 CFR Part 60,Subpart AAA.
1400
12IN/PO (305 mm) A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
12IN/PO (305 mm)
6IN/PO (152 mm)
1400
10IN/PO (254 mm)
6IN/PO (152 mm)
4IN/PO (102 mm)
S4
16IN/PO (406 mm)
6IN/PO (152 mm)
4IN/PO (102mm)
CEILING / PLAFOND
C
D
B
A
FLOOR / PLANCHER
CLEARANCES TO COMBUSTIBLE CONSTRUCTION /
D
ÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES:
(MEASURED TO UNIT / À PARTIR DE L’APPAREIL)
A SIDE FACING / CÔTÉ 1 IN/PO (25mm)
*
B TOP FACING / DESSUS 28 IN/PO (710mm)
C MANTEL / TABLETTE 28 IN/PO (710mm)
D SIDE WALL / MUR LATÉRAL 17 IN/PO (430mm)
*
CLEARANCE TO EDGE OF FLASHING / DÉGAGEMENT AU
BORD DE LA FAÇADE
3.5 Grams Per Hour / 2015 Crib Wood / 3.5 Grammes par heure / Crib Wood 2015
MANUFACTURE DATE: / DATE DE FABRICATION:
YEAR:
2016
2017
2018
MONTH:
2019
2020
2 43 65 87 109 1211
1
THIS WOOD APPLIANCE NEEDS PERIODIC INSPECTION AND REPAIR FOR
PROPER OPERATION. CONSULT THE OWNER'S MANUAL FOR FURTHER
INFORMATION. IT IS AGAINST UNITED STATES FEDERAL REGULATIONS TO
OPERATE THIS WOOD APPLIANCE IN A MANNER INCONSISTENT WITH THE
OPERATING INSTRUCTIONS IN THE OWNER'S MANUAL.
CET APPAREIL AU BOIS DOIT FAIRE L'OBJECT D'UNE INSPECTION ET D'UN
ENTRETIEN PÉRIODIQUES POUR UN FONCTIONNEMENT ADÉQUAT. CONSULTEZ
LE MANUEL D'INSTRUCTIONS POUR PLUS D'INFORMATION. LES RÈGLEMENTS
FÉDÉRAUX DE L'ÉTATS-UNIS INTERDISENT D'UTILISER CET APPAREIL DE
CHAUFFAGE D'UNE MANIÈRE ALLANT À L'ENCONTRE DES INSTRUCTIONS DE
FONCTIONNEMENT CONTENUES DANS CE MANUEL.
CORRECTED ADHESIVE TEMPERATURE LIMIT
A
B
1400 SERIES RATING PLATE ILLUSTRATED
For rating plate location, see
“INSTALLATION OVERVIEW” section.
This illustration is for reference
only. Refer to the rating plate on the
appliance for accurate information.
NOTE: The rating plate must remain
with the appliance at all times. It
must not be removed.
SAMPLE
W415-1469 / C / 08.20.18
9
EN
3.0 INSTALLATION PLANNING
Clean all ashes out of the inside of the existing fireplace opening. Make sure that the chimney and fireplace are free
of cracks, loose mortar, creosote deposits, blockage or other signs of deterioration. If necessary, have any repair
work done by a qualified professional before installing the insert.
Do NOT remove bricks or mortar from the fireplace. In case of an outside air inlet or ash dump, fill with fiberglass
insulation. Adhere to minimum clearances as illustrated.
Do NOT place any combustible materials (furniture, firewood, etc.) within 48"(121.9cm) in front of 36" (91.4cm) at the
sides of the insert.
Combustible material must not protrude more than 1" (25mm) to the side of the insert or between the mantel and
the top of the insert.
SIDEWALL
COMBUSTIBLE MANTEL
NON-COMBUSTIBLE
FACING
A
F
G
E
C
B
D
NON-COMBUSTIBLE
HEARTH AND THERMAL
FLOOR PROTECTOR
NON-COMBUSTIBLE
FACING
COMBUSTIBLE MANTEL
NON-COMBUSTIBLE
HEARTH AND THERMAL
FLOOR PROTECTOR
H
N
J
K
L
I
O
P
M
MINIMUM CLEARANCES
1101 1402
A
Sidewall
17" (43.2cm) 17" (43.2cm)
B
Mantel
28" (71.1cm) 28" (71.1cm)
C
Top facing
28" (711mm) 28" (71.1cm)
D
Side facing
1" (25mm) 1" (25mm)
E
Hearth (front) Canada 18"
(45.5cm)
US 16" (40.6cm)
Canada 18"
(45.5cm)
US 16"(40.6cm)
F
Hearth (side)
8" (203mm) 8" (203mm)
G
Objects in
front of insert
48" (121.9cm) 48" (121.9cm)
MINIMUM FIREPLACE SIZE
H
Width (rear)
24" (61cm) 25" (63.5cm)
I
Width (front)
28.5" (72.4cm) 26" (66cm)
J
Height (front)
22" (55.8cm) 22" (55.8cm)
K
Height (rear)
22" (55.8cm) 22" (55.8cm)
L
Depth 16 1/2" (41.9cm) to
21" (53.3cm)
14 1/2" (36.8cm)
M
Hearth width
39" (99cm) 39" (99cm)
N
Facing width
46 1/2" (118.1cm) 46 1/2" (118.1cm)
O
Facing height
48 1/2" (123.2cm) 47 3/4" (121.3cm)
P
Mantel
48 1/2" (123.2cm) 47 3/4" (121.3cm)
3.1 MINIMUM CLEARANCE TO COMBUSTIBLES
HEARTH EXTENSION / FLOOR PROTECTION:
Must be non-combustible and extend in front of
the insert and 8" (203mm) on both sides with a
minimum thickness of 1/2" (13mm) and a thermal
conductivity factor (K) 0.84.
W415-1469 / C / 08.20.18
10
EN
4.0 INSTALLATION
68.3C
!
WARNING
WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION.
CAREFULLY FOLLOW THE INSTRUCTIONS FOR ASSEMBLY OF THE PIPE AND OTHER PARTS
NEEDED TO INSTALL THE APPLIANCE. FAILURE TO DO SO MAY RESULT IN A FIRE, ESPECIALLY IF
COMBUSTIBLES ARE TOO CLOSE TO THE APPLIANCE OR CHIMNEY AND AIR SPACES ARE
BLOCKED, PREVENTING THE FREE MOVEMENT OF COOLING AIR.
DO NOT DRAW OUTSIDE AIR FROM GARAGE SPACES. EXHAUST PRODUCTS OF GASOLINE ENGINES
ARE HAZARDOUS. DO NOT INSTALL OUTSIDE AIR DUCTS SUCH THAT THE AIR MAY BE DRAWN
FROM ATTIC SPACES, BASEMENTS OR ABOVE THE ROOFING WHERE OTHER HEATING APPLIANCES
OR FANS AND CHIMNEYS EXHAUST OR UTILIZE AIR. THESE PRECAUTIONS WILL REDUCE THE
POSSIBILITY OF APPLIANCE SMOKING OR AIR FLOW REVERSAL. THE OUTSIDE AIR INLET MUST
REMAIN CLEAR OF LEAVES, DEBRIS ICE AND/OR SNOW. IT MUST BE UNRESTRICTED WHILE
APPLIANCE IS IN USE TO PREVENT ROOM AIR STARVATION WHICH CAN CAUSE SMOKE SPILLAGE
AND AN INABILITY TO MAINTAIN A FIRE. SMOKE SPILLAGE CAN ALSO SET OFF SMOKE ALARMS.
NEGATIVE PRESSURE WITHIN YOUR HOME MAY INADVERTENTLY AFFECT YOUR APPLIANCE.
TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION, THE APPLIANCE MUST NOT BE
INSTALLED AGAINST VAPOUR BARRIERS OR EXPOSED INSULATION. LOCALIZED OVERHEATING
COULD OCCUR AND A FIRE COULD RESULT.
DO NOT USE MAKESHIFT COMPROMISES DURING INSTALLATION. DO NOT BLOCK OR RESTRICT
AIR, GRILLE OR LOUVRE OPENINGS. DO NOT ADD A HOOD.
TO PREVENT PERSONAL INJURY KEEP HAND TOOLS IN GOOD CONDITION, SHARPEN CUTTING
EDGES AND MAKE SURE TOOL HANDLES ARE SECURE.
ALWAYS MAINTAIN THE MINIMUM AIR SPACE REQUIRED TO THE ENCLOSURE TO PREVENT FIRES.
Chimney and liner must be in good condition and kept clean.
W415-1469 / C / 08.20.18
11
EN
You can install your appliance using your existing masonry chimney. To do
so, follow the guidelines below. If you are using a masonry chimney, it
is important that it be built in compliance with the specifi cations of the
Building Code in your region. It must normally be lined with fi re clay
bricks, metal or clay tiles sealed together with fi re cement. (Round
ues are the most effi cient).
62.2
FOLLOW MANUFACTURER’S
INSTRUCTIONS FOR
MAXIMUM LINER EXTENSION
ABOVE CHIMNEY
FLOOR
PROTECTOR
DAMPER PLATE
REMOVED OR
FASTENED IN OPEN
POSITION
SEAL WITH NON-
COMBUSTIBLE
MATERIAL
MASONRY
CHIMNEY MUST
HAVE
STRUCTURAL
INTEGRITY
LISTED
CHIMNEY
LINER
A. Remove the fireplace damper or fasten it permanently open.
* We recommend the following method of sealing off the damper area around the liner.
B. * Measure the throat of the fireplace and mark this shape on a piece of 24 gauge sheet metal (flue cover);
cut a six-inch (6 3/4" / 171mm) hole to lie directly below the fireplace flue opening. Allow two inches of
material for a flange on all sides and cut to these measurements. Bend down the flanges. If you have never
done this before, it might be a good idea to make a cardboard pattern and test it first. Fasten this flue cover
in position as high as possible with two masonry screws per side through the flanges into the fireplace.
In Canada: Install a listed 6" (152mm) diameter flexible stainless steel liner from the top of the chimney to the insert
flue collar. Attach a stainless steel liner connector or elbow to the liner and insert onto the flue collar. Fasten with
three screws. Secure the top of the liner to the chimney cap using a liner support and chimney flashing. Cap the top
of the chimney liner assembly using an approved rain cap.
In the United States: While it is not required, it is recommended that a chimney liner be installed that is continuous
from the insert to the top of the chimney, particularly when the insert is installed in a basement. For this type of con-
nection, use the “In Canada” installation instructions above.
If a continuous liner is not installed, a “direct flue connection” must be made. The direct flue connection requires a
non-combustible connector that extends from the insert into the chimney flue liner and also that the installed flue
cover be sealed below the entry point of the connector to prevent dilution of combustion products in the chimney
flue with air from inside the house. Cap the top of the chimney using an approved rain cap.
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. DO
NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
!
WARNING
4.1 TYPICAL EXISTING MASONRY
W415-1469 / C / 08.20.18
12
EN
An optional low clearance flue connector is available to facilitate hook up into a tight fitting fireplace. Consult your lo-
cal dealer for details.
NOTE: This kit should be used in conjunction with a dripless connector between the flue collar and flex
liner.
A. Having ensured that the chimney is thoroughly
clean, install the flex liner. Insert a dripless connec-
tor into the flue collar. Attach the flex liner to other
end of the adapter. Secure using 6 - #8 screws.
B. Coil the rope gasket around the insert flue collar
sealing the gap between the collar and the insert
top. Using 4 - #8 screws, attach the collar flange,
squeezing the gasket tightly into place.
C. Move the insert into place in the fireplace. Maneu-
ver the insert clips into the two slots located on
the insert top by reaching through the insert flue
collar from inside the insert.
D. Thread the #10 - 24 screw through the slot lo-
cated on the insert top and into the threaded hole on the flue connector, allowing the flue connector to be
drawn forward into place.
NOTE: Check for a good seal between the insert top and the flue connector (by holding a flashlight up
through the insert collar, etc.).
The following installation requirements must be observed when installing solid fuel burning inserts into factory
built fi replaces.
A. The factory built fi replace must be listed per UL 127 or ULC S610.
B. Clearances to any combustible material surrounding this insert as identifi ed must be followed. These
clearance requirements supersede any pre-existing facing material clearances listed for the factory
built fi replace.
C. Installation must include a full height listed chimney liner meeting HT requirements (2100°F/1149°C)
as required in UL 1777 (U.S.) or ULC S635 (Canada). The liner must be securely attached to the insert
ue collar and the chimney top.
D. Means must be provided to prevent room air passage to the chimney cavity of the fi replace. This may
be accomplished by sealing the damper area around the chimney liner, or sealing the appliance front.
E. The air fl ow within and around the appliance shall not be altered by the installation of the insert (i.e.
no louvres or cooling air inlet or outlet ports are blocked), unless specifi cally tested as such for each
factory built fi replace manufacturer and model line. NOTE: Using a louvered face plate (surround)
complies with this requirement.
F. Alteration of the appliance in any manner is not permitted with the following exceptions;
A. External trim pieces which do not affect the operation of the appliance may be removed providing
they can be stored on or within the fi replace for reassembly if the insert is removed.
B. The chimney damper may be removed to install the chimney liner.
G. Circulating air chambers (i.e. in a steel fi replace liner or metal heat circulator) shall not be blocked.
H. Means must be provided for removal of the insert to clean the chimney fl ue.
I. Inserts that project in front of the fi replace must be supplied with appropriate support means.
J. A permanent metal warning label must be attached to the back of the fi replace stating that the fi replace
must be restored to its original condition for safe use without the insert.
80.2B
4.2 FACTORY BUILT FIREPLACE
4.3 LOW CLEARANCE FLUE CONNECTOR (1402)
W415-1469 / C / 08.20.18
13
EN
5.0 FINISHING
A. Install (1101) four (A) bricks and one (C) brick or (1402) six (A) bricks along both sides of the appliance.
Before installing the back bricks, loosen the screw holding the retainer and ensure that it has been moved
forward. Install the four (A) bricks and two (D) bricks along the back wall by pivoting the bricks up under
the brick retainer. Retighten the screw. NOTE: Center (D) bricks have been notched.
B. Carefully pivot fibre baffle (G) and (H) up onto the top of the side brick. Slide it over onto the flange of the
manifold. Ensure that the top baffles are pushed all the way to the rear of the firebox, leaving a minimum
of a 1" (25mm) gap along the front. This will allow the flue gases to escape the firebox.
C. Install the bottom (1101) four (A) bricks and two (B) bricks or (1402) six (A) bricks and two (B) bricks,
working from the back of the appliance forward.
D. Install the two (B) bricks, one (E) brick and one (F) brick along the front as illustrated.
NOTE: Do not operate if baffle and manifold shield are not in position.
5.1 BRICKS AND BAFFLES INSTALLATION
!
WARNING
OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE
TEMPERATURES THAT COULD DAMAGE THE APPLIANCE, CHIMNEY AND THE SURROUNDING
ENCLOSURE.
1101 1402
D
D
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
E
F
I
J
G
F
NOTE: BRICKS
E & F ARE
NOTCHED AT
REAR.
H
(Fibre Baffles)
W018-0078 X2
BRICK
RETAINERS
A
A
A
A
A
A
E
K
K
K
A
A
A
A
A
A
A
A
A
A
A
A
A
D
D
B
B
C
C
E
F
I
J
G
NOTE: BRICKS
E & F ARE
NOTCHED AT
REAR.
H
(Fibre Baffles)
W018-0077 X2
BRICK
RETAINERS
RETENUE
DU BRIQUE
K
A
A
A
A
A
A
A
A
A
A
A
A
D
D
B
B
C
E
F
I
J
G
E
F
NOTE:
BRIQUES E & F
SONT ENTAILLÉ
À ARRIÈRE
H
(Déflecteurs
en Fibre)
W018-0077 X2
E
F
K
K
A
C
K
K
K
FIREBRICK
DIMENSIONS
PART #
FIREBRICK
DIMENSIONS
PART #
1101 1402 1101 1402
A
4 1/2” x 9”
(114mm x 229mm)
W090-0001
X15
W090-0001
X21
F
4 1/2” x 9”
(Notched)
(114mm x 229mm)
W090-0208
X1
W090-0208
X1
B
3” x 9” (Molded)
(6mm x 229mm)
W090-0002
X2
W090-0002
X2
G
2 1/4” x 9”
(57mm x 229mm)
W090-0018
X1
W090-0018
X1
C
4 1/2” x 4 1/2”
(114mm x 144mm)
W090-0003
X2
N/A
H
2 1/4” x 6 1/8”
(64mm x 121mm)
W090-0019
X1
W090-0019
X1
D
3” x 9”
(76mm x 229mm)
W090-0166
X2
W090-0166
X2
I
2 1/2” x 4 1/2”
(64mm x 114mm)
W090-0016
X1
W090-0016
X1
E
4 1/2” x 9”
(Notched)
(114mm x 229mm)
W090-0207
X1
W090-0207
X1
J
1 1/2” x 4 1/2”
(38mm x 114mm)
W090-0017
X1
W090-0017
X1
All Firebricks are 1 1/4” (32mm) Thick
W415-1469 / C / 08.20.18
14
EN
5.2 DOOR REMOVAL / INSTALLATION
Hang the door using the hinge pins supplied.
Twist the large wire handle over the end of the handle rod. Twist the smaller wire handle over the end of the air damper rod
below the door.
1402
ILLUSTRATED
5.3 DOOR HANDLE INSTALLATION
!
WARNING
BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIREE HAZARD THAT
MAY RESULT IN A HOUSE AND/OR CHIMNEY FIRE.
DO NOT STRIKE OR SLAM DOOR.
NEVER REMOVE THE DOOR WHEN THE APPLIANCE IS HOT.
DOOR
HANDLE
DOOR HANDLE
LATCH
LOCK
NUT
DOOR
SPACER
FRONT VIEW
NOTE: Position of
door handle latch.
98.1
NOTE: DOOR MAY NOT BE AS
ILLUSTRATED
SPRING
WASHER
W415-1469 / C / 08.20.18
15
EN
5.4 FLASHING INSTALLATION
The top flashing has been shipped flat. To install the flashing, rest the bottom against the top of the appliance and
secure using the tabs as illustrated below.
Slide the trim over the flashing.
1402 illustrated. For 1101 flashing instructions, please refer to the leaflet provided within the flashing kit.
W415-1469 / C / 08.20.18
16
EN
6.0 OPERATION
Your Napoleon EPA listed product is designed with the most advanced technology. The appliance is extremely
airtight. It has an exclusive direct outside air supply (optional kit), a safety feature designed to prevent spillage, and
to keep your house free of carbon monoxide, in case of a down drafting chimney or an internal negative pressure.
The first fire(s) in your appliance will be difficult to get going and keep going with little amount of heat being
generated. This is a result of the moisture being driven out of the fire brick. During the break-in period (the first 2 or
3 fires) create only small, fires using kindling; this will allow the firebrick to cure. Do not be alarmed if small hairline
cracks develop in the firebrick. This is a normal occurrence and does not pose a safety hazard. The paint may also
smell a little for the first few fires as it cures and you may wish to open a door or window to alleviate the smell.
To start, a brisk fire is required. Place loosely crumpled paper on the floor of the appliance and cover with dry
kindling. Open the draft control fully by pulling the lever forward. Light the paper and leave the door slightly ajar
(one inch) until all kindling is burning. To maintain a brisk fire, a hot coal bed must be established and maintained.
Slowly add larger wood (2x4 size pieces). Lay the pieces lengthwise from side to side in the hot coal bed with a
shallow trench between, so that the primary air can flow directly into this trench and ignite the fuel above. When
the fire seems to be at its peak, medium sized logs may be added. Once these logs have caught fire, carefully
close the door. (Closing the door too quickly after refuelling will reduce the firebox temperature and result in an
unsatisfactory burn.) Remember it is more efficient to burn medium sized wood, briskly, and refuel frequently than
to load the appliance with large logs that result in a smouldering, inefficient fire and dirty glass.
As soon as the door is closed, you will observe a change in the flame pattern. The flames will get smaller and
lazier because less oxygen is getting into the combustion chamber. The flames, however, are more efficient. The
flames will remain lazy but become larger again as soon as the firebricks have been heated thoroughly and the
chimney becomes heated and provides a good draft. At this point, the roaring fire that you see when the door is
opened is wastefully drawing heated room air up the chimney -- certainly not desirable. Always operate with the
door fully closed once the medium sized logs have caught fire.
!
WARNING
ALWAYS OPERATE THIS APPLIANCE WITH THE DOOR CLOSED AND LATCHED EXCEPT DURING
START UP AND RE-FUELING. ALWAYS WEAR GLOVES TO PREVENT INJURY. DO NOT LEAVE THE
FIRE UNATTENDED WHEN THE DOOR IS UNLATCHED AS UNSTABLE WOOD COULD FALL OUT OF
THE FIRE CHAMBER CREATING A FIRE HAZARD TO YOUR HOME.
NEVER LEAVE CHILDREN UNATTENDED WHEN THERE IS A FIRE BURNING IN THE APPLIANCE.
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID,
OR SIMILAR LIQUIDS TO START OR ‘FRESHEN UP’ A FIRE IN THIS APPLIANCE. KEEP ALL SUCH
LIQUIDS WELL AWAY FROM THE APPLIANCE WHILE IT IS IN USE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE SHOULD BE KEPT A MINIMUM OF 48”
FROM THE FRONT FACE.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE
TESTING AUTHORITY IS CONSIDERED BREACHING CSA B365 (CANADA) AND ANSI NFPA 211 (USA).
OPEN AIR CONTROL (AND DAMPER WHEN FITTED) BEFORE OPENING FIRING DOOR.
HOT WHILE IN OPERATION, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS. WEAR GLOVES TO OPERATE YOUR APPLIANCE.
BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD
THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE.
THIS WOOD APPLIANCE HAS A MANUFACTURER-SET MINIMUM LOW BURN RATE THAT MUST
NOT BE ALTERED. IT IS AGAINST FEDERAL REGULATIONS IN THE UNITED STATES TO ALTER THIS
SETTING OR OTHERWISE OPERATE THIS WOOD APPLIANCE IN A MANNER INCONSISTENT WITH
OPERATING INSTRUCTIONS IN THIS MANUAL.
W415-1469 / C / 08.20.18
17
EN
You can now add larger pieces of wood and operate the appliance normally. Once the appliance is entirely hot,
it will burn very efficiently with little smoke from the chimney. There will be a bed of orange coals in the firebox
and secondary flames flickering just below the top firebrick. You can safely fill the firebox with wood to the top of
the door and will get best burns if you keep the appliance pipe temperatures between 250°F (120°C ) and 450°F
(270°C ). A surface thermometer placed on the front top will help regulate this.
Without an appliance thermometer, you are working blindly and have no idea of how the appliance is operating! An
appliance thermometer offers a guide to performance.
Can’t get the fire going?
Use more kindling and paper. Assuming the chimney and vent are sized correctly and there is sufficient
combustion air, the lack of sufficiently dry quantities of small kindling is the problem. Thumb size is a good gauge
for small kindling diameter.
Can’t get heat out of the appliance?
One of two things may have happened. The appliance door may have been closed prematurely and the appliance
itself has not reached optimum temperature. Reopen the door and/or draft control to re-establish a brisk fire. The
other problem may have been wet wood. The typical symptom is sizzling wood and moisture being driven from
the wood.
For optimal emissions performance and efficiency follow these simple guidelines when using your appliance:
A. Maintain a 2" (51mm) deep, hot, glowing red coal bed.
B. Burn dry seasoned wood with less than 20% moisture content and burn so that the glass door remains
clean.
C. A stove thermometer should indicate 350°F (176°C) as an average temperature.
D. Maintain a minimal trace of smoke coming from the chimney when the appliance is burning as intended.
E. Inspect and replace all necessary components such as gaskets, manifolds, glass and other components
which may affect the overall appliance performance.
F. Ensure an adequate draft to control burn rate and temperature.
Refer to “OPERATION” and “MAINTENANCE” sections for detailed information.
6.1 OPTIMUM BURN METHOD
W415-1469 / C / 08.20.18
18
EN
THIS WOOD APPLIANCE HAS A MANUFACTURER-SET MINIMUM LOW BURN RATE THAT MUST
NOT BE ALTERED. IT IS AGAINST FEDERAL REGULATIONS IN THE UNITED STATES TO ALTER THIS
SETTING OR OTHERWISE OPERATE THIS WOOD APPLIANCE IN A MANNER INCONSISTENT WITH
OPERATING INSTRUCTIONS IN THIS MANUAL.
Draft is the force which moves air from the firebox up through the
chimney. The amount of draft in your chimney depends on the length
and diameter of chimney, local geography, nearby obstructions and
other factors including the amount of heat generated by the fire
which can be measured by an appliance thermometer.
Adjusting the air control regulates the temperature. The draft can be
adjusted from a low burn rate with the handle in fully, to a fast burn
rate with the handle fully out.
Inadequate draft may cause back-puffing into the room through the
appliance and chimney connector points and may cause plugging of
the chimney. Too much draft may cause an excessive temperature in the appliance, glowing red appliance parts
or chimney connectors or an uncontrollable burn which can lead to a chimney fire or permanent damage to the
appliance.
Do not operate your appliance for longer than 30 minutes with the draft control on “HIGH” (fully open).
ASH LIP
91.1A
All homes with a solid fuel burning appliance should have at least one fi re extinguisher in a central location,
known to all and at least one smoke detector and carbon monoxide (CO) detector in the room containing the
appliance. If the smoke detector sounds an alarm, correct the cause but do not de-activate or relocate the
smoke detector. If the carbon monoxide detector sounds an alarm, immediately vent the area, evacuate and
call your local fi re department.
NOTE: Always check your smoke and CO detectors are working properly.
!
WARNING
!
WARNING
Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to prevent
drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this
condition is not covered by the warranty policy. Use of the blower increases the output of heat.
The 1402 inserts comes equipped with two blowers, while the 1101 has one blower. These blowers are thermally
activated and will not operate until the thermal switch reaches temperature (approximately 15-30 minutes
depending on the intensity of the fire). The thermal switch for the 1402 is located on the right hand side of the unit
and the 1101 has a thermal switch located at the back on the blower access door. When first starting the fire,
the switch may be impeded by a large log or an unevenly burning fire, causing the blowers to cycle on and off. To
control this, either build your fire up evenly or turn down the blowers until the right side of the firebox is hot.
RISK OF FIRE AND ELECTRICAL SHOCK.
TURN OFF THE ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, ETC.)
COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
ENSURE THAT THE BLOWER’S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE
APPLIANCE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER
CORD BENEATH THE APPLIANCE.
6.2 BLOWER
6.3 AIR CONTROL
6.4 FIRE EXTINGUISHERS / SMOKE & CARBON MONOXIDE DETECTORS
W415-1469 / C / 08.20.18
19
EN
6.5 FUEL
87.1E
When loading the appliance, ensure that the upper fi bre baffl e is situated properly. For maximum effi ciency, when the appliance
is thoroughly hot, load it fully to the top of the door opening and burn at a medium low setting. The whiteness of the bricks
and the cleanliness of the glass are good indicators of your operating effi ciency. Not enough heat is produced when only a few
pieces of wood are burned and/or the wood may not burn completely.
NOTE: When loading the appliance, ensure to keep fuel back from the glass. If coals are to accumulate on the front lip,
there is a chance they will fall out when the door is opened.
TYPES OF WOOD
Both hardwood and softwood burn equally well in this appliance but hardwood is denser, will weigh more per cord and burn a
little slower and longer.
Manufactured fi relogs made by compressing 100% natural wood fi bre can be safely used as fuel. Do not use manufactured
relogs if they contain additives such as paraffi n, wax, binders etc. Never burn more than two manufactured fi relogs at a
time.
MOISTURE CONTENT
Burn only dry, clean unpainted wood that has been seasoned. It produces more heat and less soot or creosote. Freshly cut
wood contains about 50% moisture while after proper seasoning only about 20% of the water remains. As wood is burned,
this water boils off consuming energy that should be used in heating. The wetter the wood, the less heat is given off and the
more creosote is produced. Dry fi rewood has cracks in the end of the grain.
STORING WOOD
Firewood should be split and stacked in a manner
that allows for full air circulation and covered in early
spring to be ready for burning that fall. Dry fi rewood
has cracks in the end grain.
Cut the wood so that it will fi t horizontally, front
to back, making for easier loading and less of a
likelihood that the wood will roll onto the glass.
Fuel for the appliance must not be stored closer
than the required clearances to combustibles (heat
sensitive material). NEVER STORE WOOD IN THE
ASH PAN COMPARTMENT (if applicable).
!
WARNING
THIS APPLIANCE IS DESIGNED TO BURN NATURAL WOOD ONLY. DO NOT BURN TREATED
WOOD, COAL, CHARCOAL, COLOURED PAPER, CARDBOARD, SOLVENTS OR GARBAGE. THIS
APPLIANCE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE RISK OF FIRE OR INJURY, DO NOT
INSTALL AN UNVENTED GAS LOG SET INTO THE APPLIANCE.
HIGHER EFFICIENCIES AND LOWER EMISSIONS GENERALLY RESULT WHEN BURNING AIR DRIED SEASONED HARDWOODS,
AS COMPARED TO SOFTWOODS OR TOO GREEN OR FRESHLY CUT HARDWOODS.
BURNING WET UNSEASONED WOOD CAN CAUSE EXCESSIVE CREOSOTE ACCUMULATION. WHEN IGNITED IT CAN CAUSE A
CHIMNEY FIRE THAT MAY RESULT IN A SERIOUS HOUSE FIRE.
DO NOT STORE FUEL WITHIN THE CLEARANCE TO COMBUSTIBLES, OR IN THE SPACE REQUIRED FOR RE-FUELING AND
ASH REMOVAL.
W415-1469 / C / 08.20.18
20
EN
93.1
A ash fi re is a small fi re burned quickly when you don't need much
heat. After your kindling has "caught", load at least 3 pieces of wood,
stacked loosely. Burn with the draft control fully open or closed only
slightly.
82.1
Load your larger pieces of wood so they are tightly packed, close enough to prevent the fl ames from
penetrating it completely. After approximately 30 minutes, depending on the size of the load, close the draft
control completely making sure that the fi re is not extinguished.
DO NOT OVERFIRE THE
APPLIANCE!
Overfi ring can occur by:
A.
Burning large amounts of smaller wood pieces such as furniture scraps, skids or treated wood;
B. Vigorously burning large loads of wood with the draft control on “HIGH” (fully open) for long periods of
time (one or two hours).
C.
Operating the appliance with the ash dump door blocked open or a poor gasket seal on the main door.
Has a direct flue connection been used rather than a chimney liner continuous from cap to appliance flue
collar?
83.1A
A properly installed appliance should not smoke. If yours does, check the following:
Has the chimney had time to get hot?
Is the smoke passage blocked anywhere in the appliance, chimney connector or chimney?
Is the room too airtight and the air intake not connected to the outside? Try with a window partly open.
Is the smoke fl ow impeded by too long a horizontal pipe or too many bends?
Is it a weak draft perhaps caused by a leaky chimney, a cold outside chimney, too large a diameter of a
chimney, too short a chimney, or a chimney too close to trees or a higher roof?
Is the moisture content of the wood greater than 20%?
If equipped, has the catalyst bypass been closed or closed prematurely?
6.6 LIGHTING A FIRE
6.6.1 FLASH FIRE
6.6.2 EXTENDED FIRE
6.7 SMOKING
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

NAPOLEON EPI-1402M Manuel utilisateur

Catégorie
Poêles
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues